Tablica podataka za ETVZ12E6V / EPRA08-12EW

ETVZ12S18EA6V / EPRA08EAW1 ETVZ12S23EA6V / EPRA08EAW1 ETVZ12S18EJ6V / EPRA08EAW1 ETVZ12S23EJ6V / EPRA08EAW1 ETVZ12S18EA6V / EPRA10EAW1 ETVZ12S23EA6V / EPRA10EAW1 ETVZ12S18EJ6V / EPRA10EAW1 ETVZ12S23EJ6V / EPRA10EAW1 ETVZ12S18EA6V / EPRA12EAW1 ETVZ12S23EA6V / EPRA12EAW1 ETVZ12S18EJ6V / EPRA12EAW1 ETVZ12S23EJ6V / EPRA12EAW1
Unutarnja jedinica ETVZ12S18EA6V ETVZ12S23EA6V     ETVZ12S18EA6V ETVZ12S23EA6V     ETVZ12S18EA6V ETVZ12S23EA6V
Učin grijanja Min. kW 3.44 (1) 3.44 (1) 3.44 (1) 3.44 (1) 3.44 (1) 3.44 (1) 3.44 (1) 3.44 (1) 3.44 (1) 3.44 (1) 3.44 (1) 3.44 (1)
  Nom. kW 6.17 (2) 6.17 (2) 6.17 (2) 6.17 (2) 6.17 (2) 6.17 (2) 6.17 (2) 6.17 (2) 6.17 (2) 6.17 (2) 6.17 (2) 6.17 (2)
  Maks. kW 7.95 (1) 7.95 (1) 7.95 (1) 7.95 (1) 9.25 (1) 9.25 (1) 9.25 (1) 9.25 (1) 9.97 (1) 9.97 (1) 9.97 (1) 9.97 (1)
Ulazna struja Grijanje Min. kW 0.70 (5) 0.70 (5) 0.70 (5) 0.70 (5) 0.70 (5) 0.70 (5) 0.70 (5) 0.70 (5) 0.70 (5) 0.70 (5) 0.70 (5) 0.70 (5)
    Nom. kW 1.21 (2) 1.21 (2) 1.21 (2) 1.21 (2) 1.21 (2) 1.21 (2) 1.21 (2) 1.21 (2) 1.21 (2) 1.21 (2) 1.21 (2) 1.21 (2)
    Maks. kW 1.63 (5) 1.63 (5) 1.63 (5) 1.63 (5) 1.98 (5) 1.98 (5) 1.98 (5) 1.98 (5) 2.21 (5) 2.21 (5) 2.21 (5) 2.21 (5)
Ulazna snaga Potrošna topla voda od 10°C do 50 °C Nom. kWh 2.54 (6) 3.09 (6) 2.54 (6) 3.09 (6) 2.54 (6) 3.09 (6) 2.54 (6) 3.09 (6) 2.54 (6) 3.09 (6) 2.54 (6) 3.09 (6)
Vrijeme zagrijavanja od 10°C do 50 °C. hr 1 sat 51 min. 1 sat 10 min. 1 sat 51 min. 1 sat 10 min. 1 sat 51 min. 1 sat 10 min. 1 sat 51 min. 1 sat 10 min. 1 sat 51 min. 1 sat 10 min. 1 sat 51 min. 1 sat 10 min.
COP 5.10 (2) 5.10 (2) 5.10 (2) 5.10 (2) 5.10 (2) 5.10 (2) 5.10 (2) 5.10 (2) 5.10 (2) 5.10 (2) 5.10 (2) 5.10 (2)
Grijanje potrošne tople vode Općenito Deklarirani profil opterećenja   L L L L L L L L L L L L
  Prosječni klimatski uvjeti Razred energetske učinkovitosti grijanja vode   A+ A+ A+ A+ A+ A+ A+ A+ A+ A+ A+ A+
Grijanje prostora Izlaz za vodu u prosječnoj klimi 55°C Općenito SCOP   3.52 3.52 3.52 3.52 3.53 3.53 3.53 3.53 3.53 3.53 3.53 3.53
      Razred sezonske učinkovitosti grijanja prostora   A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++ A++
  Izlaz za vodu u prosječnoj klimi 35°C Općenito SCOP   4.81 4.81 4.81 4.81 4.84 4.84 4.84 4.84 4.84 4.84 4.84 4.84
      Razred sezonske učinkovitosti grijanja prostora   A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++
Raspon energetske učinkovitosti Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F
Napomene (1) - Učin je u skladu s normom EN14511 i valjan je za raspon grijane vode dT = 3~8°C at Ta 7°C (1) - Učin je u skladu s normom EN14511 i valjan je za raspon grijane vode dT = 3~8°C at Ta 7°C (1) - Učin je u skladu s normom EN14511 i valjan je za raspon grijane vode dT = 3~8°C at Ta 7°C (1) - Učin je u skladu s normom EN14511 i valjan je za raspon grijane vode dT = 3~8°C at Ta 7°C (1) - Učin je u skladu s normom EN14511 i valjan je za raspon grijane vode dT = 3~8°C at Ta 7°C (1) - Učin je u skladu s normom EN14511 i valjan je za raspon grijane vode dT = 3~8°C at Ta 7°C (1) - Učin je u skladu s normom EN14511 i valjan je za raspon grijane vode dT = 3~8°C at Ta 7°C (1) - Učin je u skladu s normom EN14511 i valjan je za raspon grijane vode dT = 3~8°C at Ta 7°C (1) - Učin je u skladu s normom EN14511 i valjan je za raspon grijane vode dT = 3~8°C at Ta 7°C (1) - Učin je u skladu s normom EN14511 i valjan je za raspon grijane vode dT = 3~8°C at Ta 7°C (1) - Učin je u skladu s normom EN14511 i valjan je za raspon grijane vode dT = 3~8°C at Ta 7°C (1) - Učin je u skladu s normom EN14511 i valjan je za raspon grijane vode dT = 3~8°C at Ta 7°C
  (2) - Uvjet: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Uvjet: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Uvjet: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Uvjet: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Uvjet: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Uvjet: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Uvjet: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Uvjet: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Uvjet: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Uvjet: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Uvjet: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Uvjet: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (3) - Ulazna snaga je ukupna snaga unutarnjih i vanjskih jedinica, uključujući cirkulacijsku crpku; u skladu s EN14511 (3) - Ulazna snaga je ukupna snaga unutarnjih i vanjskih jedinica, uključujući cirkulacijsku crpku; u skladu s EN14511 (3) - Ulazna snaga je ukupna snaga unutarnjih i vanjskih jedinica, uključujući cirkulacijsku crpku; u skladu s EN14511 (3) - Ulazna snaga je ukupna snaga unutarnjih i vanjskih jedinica, uključujući cirkulacijsku crpku; u skladu s EN14511 (3) - Ulazna snaga je ukupna snaga unutarnjih i vanjskih jedinica, uključujući cirkulacijsku crpku; u skladu s EN14511 (3) - Ulazna snaga je ukupna snaga unutarnjih i vanjskih jedinica, uključujući cirkulacijsku crpku; u skladu s EN14511 (3) - Ulazna snaga je ukupna snaga unutarnjih i vanjskih jedinica, uključujući cirkulacijsku crpku; u skladu s EN14511 (3) - Ulazna snaga je ukupna snaga unutarnjih i vanjskih jedinica, uključujući cirkulacijsku crpku; u skladu s EN14511 (3) - Ulazna snaga je ukupna snaga unutarnjih i vanjskih jedinica, uključujući cirkulacijsku crpku; u skladu s EN14511 (3) - Ulazna snaga je ukupna snaga unutarnjih i vanjskih jedinica, uključujući cirkulacijsku crpku; u skladu s EN14511 (3) - Ulazna snaga je ukupna snaga unutarnjih i vanjskih jedinica, uključujući cirkulacijsku crpku; u skladu s EN14511 (3) - Ulazna snaga je ukupna snaga unutarnjih i vanjskih jedinica, uključujući cirkulacijsku crpku; u skladu s EN14511
  (4) - Ispitano pri Ta DB/WB 7 °C/6 °C prema EN 16147. (4) - Ispitano pri Ta DB/WB 7 °C/6 °C prema EN 16147. (4) - Ispitano pri Ta DB/WB 7 °C/6 °C prema EN 16147. (4) - Ispitano pri Ta DB/WB 7 °C/6 °C prema EN 16147. (4) - Ispitano pri Ta DB/WB 7 °C/6 °C prema EN 16147. (4) - Ispitano pri Ta DB/WB 7 °C/6 °C prema EN 16147. (4) - Ispitano pri Ta DB/WB 7 °C/6 °C prema EN 16147. (4) - Ispitano pri Ta DB/WB 7 °C/6 °C prema EN 16147. (4) - Ispitano pri Ta DB/WB 7 °C/6 °C prema EN 16147. (4) - Ispitano pri Ta DB/WB 7 °C/6 °C prema EN 16147. (4) - Ispitano pri Ta DB/WB 7 °C/6 °C prema EN 16147. (4) - Ispitano pri Ta DB/WB 7 °C/6 °C prema EN 16147.
  (5) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C), s pumpom na punoj brzini (5) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C), s pumpom na punoj brzini (5) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C), s pumpom na punoj brzini (5) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C), s pumpom na punoj brzini (5) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C), s pumpom na punoj brzini (5) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C), s pumpom na punoj brzini (5) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C), s pumpom na punoj brzini (5) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C), s pumpom na punoj brzini (5) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C), s pumpom na punoj brzini (5) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C), s pumpom na punoj brzini (5) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C), s pumpom na punoj brzini (5) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C), s pumpom na punoj brzini