Tablica podataka za ETSHB-D / EPRA014-018DV

ETSHB16P30DA / EPRA14DAV3 ETSHB16P50DA / EPRA14DAV3 ETSHB16P30DA / EPRA16DAV3 ETSHB16P50DA / EPRA16DAV3 ETSHB16P30DA / EPRA18DAV3 ETSHB16P50DA / EPRA18DAV3
Indoor unit ETSHB16P30DA ETSHB16P50DA ETSHB16P30DA ETSHB16P50DA ETSHB16P30DA ETSHB16P50DA
Učin grijanja Min. kW 3.70 (1) 3.70 (1) 3.96 (1) 3.96 (1) 4.40 (1) 4.40 (1)
  Nom. kW 5.69 (2) 5.69 (2) 9.00 (2) 9.00 (2) 9.00 (2) 9.00 (2)
  Maks. kW 10.18 (1) 10.18 (1) 10.91 (1) 10.91 (1) 12.12 (1) 12.12 (1)
Ulazna struja Grijanje Min. kW 0.88 (5) 0.88 (5) 0.95 (5) 0.95 (5) 1.05 (5) 1.05 (5)
    Nom. kW 1.22 (2) 1.22 (2) 1.80 (2) 1.80 (2) 1.80 (2) 1.80 (2)
    Maks. kW 2.09 (5) 2.09 (5) 2.24 (5) 2.24 (5) 2.49 (5) 2.49 (5)
  Domestic hot water from 10°C to 50°C Nom. kWh 3.92 5.26 3.92 5.26 3.92 5.26
Heat up time from 10°C to 50°C hr 1h41min at 7°C ambient temperature 2h11min at 7°C ambient temperature 1h41min at 7°C ambient temperature 2h11min at 7°C ambient temperature 1h41min at 7°C ambient temperature 2h11min at 7°C ambient temperature
COP 4.67 (2) 4.67 (2) 5.00 (2) 5.00 (2) 5.00 (2) 5.00 (2)
Grijanje potrošne tople vode Općenito Deklarirani profil opterećenja   L XL L XL L XL
  Prosječni klimatski uvjeti Razred energetske učinkovitosti grijanja vode   A A A A A A
Grijanje prostora Izlaz za vodu u prosječnoj klimi 55°C Općenito SCOP   3.58 3.58 3.58 3.58 3.58 3.58
      Razred sezonske učinkovitosti grijanja prostora   A++ A++ A++ A++ A++ A++
      ηs (sezonska učinkovitost grijanja prostora) % 140 140 140 140 140 140
  Izlaz za vodu u prosječnoj klimi 35°C Općenito SCOP   4.51 4.51 4.51 4.51 4.51 4.51
      Razred sezonske učinkovitosti grijanja prostora   A+++ A+++ A+++ A+++ A+++ A+++
      ηs (sezonska učinkovitost grijanja prostora) % 177 177 177 177 177 177
Napomene (1) - Učin je u skladu s normom EN14511 i valjan je za raspon grijane vode dT = 3~8°C at Ta 7°C (1) - Učin je u skladu s normom EN14511 i valjan je za raspon grijane vode dT = 3~8°C at Ta 7°C (1) - Učin je u skladu s normom EN14511 i valjan je za raspon grijane vode dT = 3~8°C at Ta 7°C (1) - Učin je u skladu s normom EN14511 i valjan je za raspon grijane vode dT = 3~8°C at Ta 7°C (1) - Učin je u skladu s normom EN14511 i valjan je za raspon grijane vode dT = 3~8°C at Ta 7°C (1) - Učin je u skladu s normom EN14511 i valjan je za raspon grijane vode dT = 3~8°C at Ta 7°C
  (2) - Uvjet: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Uvjet: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Uvjet: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Uvjet: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Uvjet: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Uvjet: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (3) - Hlađenje: EW 23°C; LW 18°C; uvjeti okoline: 35°CDB (3) - Hlađenje: EW 23°C; LW 18°C; uvjeti okoline: 35°CDB (3) - Hlađenje: EW 23°C; LW 18°C; uvjeti okoline: 35°CDB (3) - Hlađenje: EW 23°C; LW 18°C; uvjeti okoline: 35°CDB (3) - Hlađenje: EW 23°C; LW 18°C; uvjeti okoline: 35°CDB (3) - Hlađenje: EW 23°C; LW 18°C; uvjeti okoline: 35°CDB
  (4) - Hlađenje: EW 12°C; LW 7°C; uvjeti okoline: 35°CDB (4) - Hlađenje: EW 12°C; LW 7°C; uvjeti okoline: 35°CDB (4) - Hlađenje: EW 12°C; LW 7°C; uvjeti okoline: 35°CDB (4) - Hlađenje: EW 12°C; LW 7°C; uvjeti okoline: 35°CDB (4) - Hlađenje: EW 12°C; LW 7°C; uvjeti okoline: 35°CDB (4) - Hlađenje: EW 12°C; LW 7°C; uvjeti okoline: 35°CDB
  (5) - Ulazna snaga je ukupna snaga unutarnjih i vanjskih jedinica, uključujući cirkulacijsku crpku; u skladu s EN14511 (5) - Ulazna snaga je ukupna snaga unutarnjih i vanjskih jedinica, uključujući cirkulacijsku crpku; u skladu s EN14511 (5) - Ulazna snaga je ukupna snaga unutarnjih i vanjskih jedinica, uključujući cirkulacijsku crpku; u skladu s EN14511 (5) - Ulazna snaga je ukupna snaga unutarnjih i vanjskih jedinica, uključujući cirkulacijsku crpku; u skladu s EN14511 (5) - Ulazna snaga je ukupna snaga unutarnjih i vanjskih jedinica, uključujući cirkulacijsku crpku; u skladu s EN14511 (5) - Ulazna snaga je ukupna snaga unutarnjih i vanjskih jedinica, uključujući cirkulacijsku crpku; u skladu s EN14511