Tablica podataka za EHSX-D / ERGA04-08DV

EHSX04P50DA / ERGA04DAV3 EHSX04P30DA / ERGA04DAV3 EHSX04P50DA7 / ERGA04DAV3 EHSX08P30DA / ERGA06DAV3 EHSX08P50DA / ERGA06DAV3 EHSX08P50DA7 / ERGA06DAV3 EHSX08P30DA / ERGA08DAV3A EHSX08P50DA / ERGA08DAV3A EHSX08P30DA / ERGA08DAV3 EHSX08P50DA / ERGA08DAV3 EHSX08P50DA7 / ERGA08DAV3
Indoor unit EHSX04P50D EHSX04P30D EHSX04P50DA7 EHSX08P30D EHSX08P50D EHSX08P50DA7 EHSX08P30D EHSX08P50D EHSX08P30D EHSX08P50D EHSX08P50DA7
Učin grijanja Nom. kW 4.30 (1), 4.60 (2) 4.30 (1), 4.60 (2) 4.30 (1), 4.60 (2) 6.00 (1), 5.90 (2) 6.00 (1), 5.90 (2) 6.00 (1), 5.90 (2) 7.50 (1), 7.80 (2) 7.50 (1), 7.80 (2) 7.50 (1), 7.80 (2) 7.50 (1), 7.80 (2) 7.50 (1), 7.80 (2)
Učin hlađenja Nom. kW 5.56 (1), 4.37 (2) 5.56 (1), 4.37 (2) 4.86 (1), 4.52 (2) 5.96 (1), 4.87 (2) 5.96 (1), 4.87 (2) 5.96 (1), 5.09 (2) 5.35 (2), 6.25 (1) 5.35 (2), 6.25 (1) 6.25 (1), 5.35 (2) 6.25 (1), 5.35 (2) 6.25 (1), 5.44 (2)
Priključna snaga Grijanje Nom. kW 0.850 (1), 1.26 (2) 0.850 (1), 1.26 (2) 0.840 (1), 1.26 (2) 1.24 (1), 1.69 (2) 1.24 (1), 1.69 (2) 1.24 (1), 1.69 (2) 1.63 (1), 2.23 (2) 1.63 (1), 2.23 (2) 1.63 (1), 2.23 (2) 1.63 (1), 2.23 (2) 1.63 (1), 2.23 (2)
  Hlađenje Nom. kW 0.940 (1), 1.14 (2) 0.940 (1), 1.14 (2) 0.810 (1), 1.36 (2) 1.06 (1), 1.33 (2) 1.06 (1), 1.33 (2) 1.06 (1), 1.55 (2) 1.16 (1), 1.51 (2) 1.16 (1), 1.51 (2) 1.16 (1), 1.51 (2) 1.16 (1), 1.51 (2) 1.16 (1), 1.73 (2)
Heat up time from 10°C to 50°C hr   1h31min   1h31min 2h57min       1h31min 2h57min  
COP 5.10 (1), 3.65 (2) 5.10 (1), 3.65 (2) 5.10 (1), 3.65 (2) 4.85 (1), 3.50 (2) 4.85 (1), 3.50 (2) 4.85 (1), 3.50 (2) 3.50 (2), 4.60 (1) 3.50 (2), 4.60 (1) 4.60 (1), 3.50 (2) 4.60 (1), 3.50 (2) 4.60 (1), 3.50 (2)
EER 5.94 (1), 3.84 (2) 5.94 (1), 3.84 (2) 5.98 (1), 3.32 (2) 5.61 (1), 3.67 (2) 5.61 (1), 3.67 (2) 5.61 (1), 3.28 (2) 3.54 (2), 5.40 (1) 3.54 (2), 5.40 (1) 5.40 (1), 3.54 (2) 5.40 (1), 3.54 (2) 5.40 (1), 3.14 (2)
Grijanje potrošne tople vode Općenito Deklarirani profil opterećenja   XL L XL L XL XL L XL L XL XL
  Prosječni klimatski uvjeti Razred energetske učinkovitosti grijanja vode   A A A A A A A   A A A
Napomene Stanje 1: hlađenje Ta 35°C - LWE 18°C (DT = 5°C); grijanje Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Stanje 1: hlađenje Ta 35°C - LWE 18°C (DT = 5°C); grijanje Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Stanje 1: hlađenje Ta 35°C - LWE 18°C (DT = 5°C); grijanje Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Stanje 1: hlađenje Ta 35°C - LWE 18°C (DT = 5°C); grijanje Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Stanje 1: hlađenje Ta 35°C - LWE 18°C (DT = 5°C); grijanje Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Stanje 1: hlađenje Ta 35°C - LWE 18°C (DT = 5°C); grijanje Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Stanje 1: hlađenje Ta 35°C - LWE 18°C (DT = 5°C); grijanje Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Stanje 1: hlađenje Ta 35°C - LWE 18°C (DT = 5°C); grijanje Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Stanje 1: hlađenje Ta 35°C - LWE 18°C (DT = 5°C); grijanje Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) Stanje 1: hlađenje Ta 35°C - LWE 18°C (DT = 5°C); grijanje Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Stanje 1: hlađenje Ta 35°C - LWE 18°C (DT = 5°C); grijanje Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  Stanje 2: hlađenje Ta 35°C - LWE 7°C (DT = 5°C); grijanje Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) Stanje 2: hlađenje Ta 35°C - LWE 7°C (DT = 5°C); grijanje Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) (2) - Stanje 2: hlađenje Ta 35°C - LWE 7°C (DT = 5°C); grijanje Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) Stanje 2: hlađenje Ta 35°C - LWE 7°C (DT = 5°C); grijanje Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) Stanje 2: hlađenje Ta 35°C - LWE 7°C (DT = 5°C); grijanje Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) (2) - Stanje 2: hlađenje Ta 35°C - LWE 7°C (DT = 5°C); grijanje Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) Stanje 2: hlađenje Ta 35°C - LWE 7°C (DT = 5°C); grijanje Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) Stanje 2: hlađenje Ta 35°C - LWE 7°C (DT = 5°C); grijanje Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) Stanje 2: hlađenje Ta 35°C - LWE 7°C (DT = 5°C); grijanje Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) Stanje 2: hlađenje Ta 35°C - LWE 7°C (DT = 5°C); grijanje Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) (2) - Stanje 2: hlađenje Ta 35°C - LWE 7°C (DT = 5°C); grijanje Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C)
Grijanje prostora Izlaz za vodu u prosječnoj klimi 55°C Općenito SCOP     3.26   3.26 3.26   3.27 3.27 3.32 3.32  
      Razred sezonske učinkovitosti grijanja prostora     A++   A++ A++   A++ A++ A++ A++  
  Izlaz za vodu u prosječnoj klimi 35°C Općenito SCOP     4.48   4.47 4.47   4.56 4.56 4.56 4.56  
      Razred sezonske učinkovitosti grijanja prostora     A++   A++ A++   A++ A++ A++ A++