FTXJ20MV1BS / RXJ20M2V1B FTXJ20MV1BS / RXJ20M3V1B FTXJ20MV1BS / RXJ20M5V1B FTXJ25MV1BS / RXJ25M3V1B FTXJ25MV1BS / RXJ25M2V1B FTXJ25MV1BS / RXJ25M5V1B FTXJ35MV1BS / RXJ35M2V1B FTXJ35MV1BS / RXJ35M3V1B FTXJ35MV1BS / RXJ35M5V1B FTXJ50MV1BS / RXJ50MV1B
Indoor unit     FTXJ20MV1BS     FTXJ25MV1BS     FTXJ35MV1BS  
Outdoor unit     RXJ20M5V1B     RXJ25M5V1B     RXJ35M5V1B  
Učin hlađenja Min. kW   1.30   0.90       0.90    
  Min. Btu/h   4,400   3,100       3,100    
  Min. Kcal/h   1,120   770       770    
  Nom. kW 2.3 2.30 2.30 2.40 2.4 2.40 3.5 3.50 3.50 4.80
  Nom. Btu/h   7,848   8,189       11,942    
  Nom. Kcal/h   1,978   2,064       3,009    
  Maks. kW   2.80   3.30       4.10    
  Maks. Btu/h   9,500   11,300       14,000    
  Maks. Kcal/h   2,410   2,840       3,530    
Učin grijanja Min. kW   1.30   0.90       0.90    
  Min. Btu/h   4,400   3,100       3,100    
  Min. Kcal/h   1,120   770       770    
  Nom. kW 2.5 2.50 2.5 3.20 3.2 3.2 4 4.00 4.0 5.80
  Nom. Btu/h   8,530   10,919       13,649    
  Nom. Kcal/h   2,150   2,752       3,439    
  Maks. kW   4.30   4.70       5.10    
  Maks. Btu/h   14,600   16,000       17,400    
  Maks. Kcal/h   3,700   4,040       4,390    
Ulazna snaga Hlađenje Nom. kW 0.50 0.50 0.50 0.51 0.51 0.51 0.86 0.86 0.86 1.43
  Grijanje Nom. kW 0.50 0.50 0.50 0.70 0.70 0.70 0.99 0.99 0.99 1.59
Nazivna učinkovitost EER   4.64 4.64 4.64 4.73 4.73 4.73 4.09 4.09 4.09 3.35
  COP   5.00 5.00 5.00 4.57 4.57 4.57 4.04 4.04 4.04 3.65
  Godišnja potrošnja energije kWh 248 248 248 254 254 254 428 428 428 716
  Direktiva o označivanju energetske učinkovitosti Hlađenje   A A A A A A A A A A
    Grijanje   A A A A A A A A A A
Hlađenje prostora Kapacitet Pdesign kW 2.30 2.30 2.3 2.40 2.40 2.4 3.50 3.50 3.5 4.80
  Razred energetske učinkovitosti   A+++ A+++ A+++ A+++ A+++ A+++ A++ A++ A++ A++
  SEER   8.73 8.73 8.73 8.64 8.64 8.64 7.19 7.19 7.19 7.02
  Godišnja potrošnja energije kWh/a 92 92 92 97 97 97 170 170 170 239
  A stanje (35°C - 27/19) Pdc kW 2.30 2.30 2.30 2.40 2.40 2.40 3.50 3.50 3.50 4.80
    EERd   4.64 4.64 4.64 4.73 4.73 4.73 4.09 4.09 4.09 3.35
    Ulaz struje kW 0.50 0.50 0.50 0.51 0.51 0.51 0.86 0.86 0.86 1.43
  B stanje (30°C - 27/19) Pdc kW 1.62 1.69 1.62 1.77 1.70 1.70 2.53 2.58 2.53 3.47
    EERd   7.67 6.83 7.67 6.59 7.33 7.33 5.44 5.44 5.44 5.24
    Ulaz struje kW 0.21 0.25 0.21 0.27 0.23 0.23 0.47 0.47 0.47 0.66
  C stanje (25°C - 27/19) Pdc kW 1.27 1.09 1.27 1.14 1.27 1.27 1.66 1.66 1.66 2.36
    EERd   10.69 10.96 10.69 10.90 10.55 10.55 7.88 7.88 7.88 8.64
    Ulaz struje kW 0.12 0.10 0.12 0.10 0.12 0.12 0.21 0.21 0.21 0.27
  D stanje (20°C - 27/19) Pdc kW 1.36 1.12 1.36 1.12 1.37 1.37 1.46 1.46 1.46 2.17
    EERd   14.25 14.56 14.25 14.28 14.16 14.16 13.76 13.76 13.76 12.00
    Ulaz struje kW 0.10 0.08 0.10 0.08 0.10 0.10 0.11 0.11 0.11 0.18
Grijanje prostora (prosječna klima) Kapacitet Pdesign kW 2.10 2.10 2.10 2.70 2.70 2.70 3.00 3.00 3.00 4.60
  Razred energetske učinkovitosti   A++ A++ A++ A++ A++ A++ A++ A++ A++ A+
  SCOP/A   4.61 4.60 4.61 4.60 4.60 4.60 4.60 4.60 4.60 4.28
  SCOPnet/A   4.65 4.65 4.65 4.65 4.66 4.66 4.64 4.64 4.64 4.30
  Pdh Heating capacity at -10° kW 1.80 1.80 1.80 2.18 2.18 2.18 2.61 2.61 2.61 4.16
  Godišnja potrošnja energije kWh/a 638 639 638 821 822 822 913 913 913 1,505
  Potrebna rezervna gornja granica grijanja u dizajniranim uvjetima kW 0.30 0.30 0.30 0.52 0.52 0.52 0.39 0.39 0.39 0.44
  TOL Tol (temperaturna granica rada) °C -15 -15 -15 -15 -15 -15 -15 -15 -15 -15
    Pdh (nazivna gornja granica grijanja) kW 1.68 1.68 1.68 1.95 1.95 1.95 2.56 2.56 2.56 4.12
    COPd (nazivni COP)   2.69 2.69 2.69 2.47 2.47 2.47 2.41 2.41 2.41 2.16
    Ulaz struje kW 0.62 0.62 0.62 0.79 0.79 0.79 1.06 1.06 1.06 1.91
  TBivalent Tbiv (bivalentna temperatura) °C -7 -7 -7 -7 -7 -7 -7 -7 -7 -7
    Pdh (nazivna gornja granica grijanja) kW 1.87 1.86 1.87 2.39 2.31 2.31 2.64 2.64 2.64 4.19
    COPd (nazivni COP)   3.40 3.46 3.40 3.17 3.10 3.10 3.10 3.10 3.10 2.47
    Ulaz struje kW 0.55 0.54 0.55 0.75 0.75 0.75 0.85 0.85 0.85 1.70
  A stanje (-7°C) Pdh (nazivna gornja granica grijanja) kW 1.87 1.86 1.87 2.39 2.31 2.31 2.64 2.64 2.64 4.19
    COPd (nazivni COP)   3.40 3.46 3.40 3.17 3.10 3.10 3.10 3.10 3.10 2.47
    Ulaz struje kW 0.55 0.54 0.55 0.75 0.75 0.75 0.85 0.85 0.85 1.70
  B stanje (2°C) Pdh (nazivna gornja granica grijanja) kW 1.07 1.13 1.07 1.45 1.40 1.40 1.53 1.53 1.53 2.49
    COPd (nazivni COP)   4.89 4.78 4.89 4.77 4.87 4.87 4.80 4.80 4.80 4.41
    Ulaz struje kW 0.22 0.24 0.22 0.30 0.29 0.29 0.32 0.32 0.32 0.56
  C stanje (7°C) Pdh (nazivna gornja granica grijanja) kW 1.00 0.73 1.00 0.93 1.00 1.00 1.07 1.07 1.07 1.63
    COPd (nazivni COP)   5.37 5.03 5.37 5.38 5.37 5.37 5.40 5.40 5.40 5.24
    Ulaz struje kW 0.19 0.15 0.19 0.17 0.19 0.19 0.20 0.20 0.20 0.31
  D stanje (12°C) Pdh (nazivna gornja granica grijanja) kW 0.96 0.87 0.96 0.87 0.96 0.96 0.99 0.99 0.99 1.87
    COPd (nazivni COP)   6.36 6.71 6.36 6.55 6.36 6.36 6.42 6.42 6.42 7.95
    Ulaz struje kW 0.15 0.13 0.15 0.13 0.15 0.15 0.15 0.15 0.15 0.24
Grijanje prostora (topla klima) Kapacitet Pdesign kW 1.07 1.07 1.07 1.40 1.40 1.40 1.53 1.53 1.53 2.49
  Razred energetske učinkovitosti   A++ A+++ A++ A+++ A+++ A+++ A+++ A+++ A+++ A+++
  SCOP   5.00 5.18 5.00 5.38 5.21 5.21 5.32 5.32 5.32 5.77
  SCOPnet   5.11 5.31 5.11 5.48 5.30 5.30 5.41 5.41 5.41 5.86
  Godišnja potrošnja energije kWh/a 300 289 300 365 376 376 403 403 403 604
  Potrebna kapica rezervnog grijača u uvjetima dizajna kW 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
  Kapacitet Tol (temperaturna granica rada) °C -15 -15 -15 -15 -15 -15 -15 -15 -15 -15
    Pdh (nazivna gornja granica grijanja) kW 1.68 1.68 1.68 1.95 1.95 1.95 2.56 2.56 2.56 4.12
    COPd (nazivni COP)   2.69 2.69 2.69 2.47 2.47 2.47 2.41 2.41 2.41 2.16
    Ulaz struje kW 0.62 0.62 0.62 0.79 0.79 0.79 1.06 1.06 1.06 1.91
  TBivalent Tbiv (bivalentna temperatura) °C 2 2 2 2 2 2 2 2 2 2
    Pdh (nazivna gornja granica grijanja) kW 1.07 1.07 1.07 1.40 1.40 1.40 1.53 1.53 1.53 2.49
    COPd (nazivni COP)   4.89 4.89 4.89 4.87 4.87 4.87 4.80 4.80 4.80 4.41
    Ulaz struje kW 0.22 0.22 0.22 0.29 0.29 0.29 0.32 0.32 0.32 0.56
  B stanje (2°C) Pdh (nazivna gornja granica grijanja) kW 1.07 1.13 1.07 1.45 1.40 1.40 1.53 1.53 1.53 2.49
    COPd (nazivni COP)   4.89 4.78 4.89 4.77 4.87 4.87 4.80 4.80 4.80 4.41
    Ulaz struje kW 0.22 0.24 0.22 0.30 0.29 0.29 0.32 0.32 0.32 0.56
  C stanje (7°C) Pdh (nazivna gornja granica grijanja) kW 1.00 0.73 1.00 0.93 1.00 1.00 1.07 1.07 1.07 1.63
    COPd (nazivni COP)   5.37 5.03 5.37 5.38 5.37 5.37 5.40 5.40 5.40 5.24
    Ulaz struje kW 0.19 0.15 0.19 0.17 0.19 0.19 0.20 0.20 0.20 0.31
  D stanje (12°C) Pdh (nazivna gornja granica grijanja) kW 0.96 0.87 0.96 0.87 0.96 0.96 0.99 0.99 0.99 1.9
    COPd (nazivni COP)   6.36 6.71 6.36 6.55 6.36 6.36 6.42 6.42 6.42 7.95
    Ulaz struje kW 0.15 0.13 0.15 0.13 0.15 0.15 0.15 0.15 0.15 0.24
Potrošnja energije u drugim načinima rada osim aktivnog Crankcase heater mode PCK W 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0
  Isključeni način rada POFF W 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0
  Način rada u stanju mirovanja Hlađenje PSB W 1.0 1.00 1.00 1.00 1.0 1.00 1.0 1.00 1.00 1.0
    Grijanje PSB W   1.0   1.0       1.0    
  Isključeni način rada termostata PTO Hlađenje W   9   9       9    
      Grijanje W   9.0 9.0 9.0   9.0   9.0 9.0  
Pto (Thermostat off) W 9.0       9.0   9.0     9.0
Rashladna tehnika Cdc (hlađenje razgradnjom)   0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25
Grijanje Cdh (grijanje razgradnjom)   0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25
Uključujući funkciju hlađenja Da Da Da Da Da Da Da Da Da Da
Uključujući funkciju grijanja Da Da Da Da Da Da Da Da Da Da
Uključujući prosječnu klimu Da Da Da Da Da Da Da Da Da Da
Uključujući hladnu sezonu Ne Ne Ne Ne Ne Ne Ne Ne Ne Ne
Uključujući toplu sezonu Ne Da Da Da Ne Da Ne Da Da Ne
Logotip eko naljepnice   Ne Ne Ne   Ne   Ne Ne Ne
Eurovent Sound power level outdoor Cooling Nom. dBA 61 61 61 61 61 61 63 63 63 63
  Unutarnja razina jačine zvuka Hlađenje Nom. dBA 54 54 54 54 54 54 59 59 59 60
Napomene (0) - EER/COP prema Eurovent 2012, za korištenje samo izvan EU       (0) - EER/COP prema Eurovent 2012, za korištenje samo izvan EU   (0) - EER/COP prema Eurovent 2012, za korištenje samo izvan EU     (1) - EER/COP prema Eurovent 2012, za korištenje samo izvan EU
  (1) - Nazivna učinkovitost: hlađenje na 35°/27° nazivnog opterećenja, grijanje na 7°/20° nazivnog opterećenja       (1) - Nazivna učinkovitost: hlađenje na 35°/27° nazivnog opterećenja, grijanje na 7°/20° nazivnog opterećenja   (1) - Nazivna učinkovitost: hlađenje na 35°/27° nazivnog opterećenja, grijanje na 7°/20° nazivnog opterećenja     (2) - Nazivna učinkovitost: hlađenje na 35°/27° nazivnog opterećenja, grijanje na 7°/20° nazivnog opterećenja
Notes_Description   1 1 1   1   1 1