Tablica podataka za ETVH-D6VG / EPRA014-018DW

ETVH16S23DA6VG / EPRA14DAW1 ETVH16S18DA6VG / EPRA14DAW1 ETVH16S23DA6VG / EPRA16DAW1 ETVH16S18DA6VG / EPRA16DAW1 ETVH16S23DA6VG / EPRA18DAW1 ETVH16S18DA6VG / EPRA18DAW1
Indoor unit ETVH16S23DA6V ETVH16S18DA6V ETVH16S23DA6V ETVH16S18DA6V ETVH16S23DA6V ETVH16S18DA6V
Outdoor unit EPRA14DAW1 EPRA14DAW1 EPRA16DAW1 EPRA16DAW1 EPRA18DAW1 EPRA18DAW1
Učin grijanja Min. kW 3.50 (1) 3.50 (1) 3.90 (1) 3.90 (1) 4.16 (1) 4.16 (1)
  Nom. kW 5.69 (2) 5.69 (2) 9.00 (2) 9.00 (2) 9.00 (2) 9.00 (2)
  Maks. kW 8.75 (1) 8.75 (1) 10.00 (1) 10.00 (1) 11.25 (1) 11.25 (1)
Ulazna struja Grijanje Min. kW 0.74 (5) 0.74 (5) 0.82 (5) 0.82 (5) 0.88 (5) 0.88 (5)
    Nom. kW 1.22 (2) 1.22 (2) 1.80 (2) 1.80 (2) 1.80 (2) 1.80 (2)
    Maks. kW 1.86 (5) 1.86 (5) 2.13 (5) 2.13 (5) 2.40 (5) 2.40 (5)
  Domestic hot water from 10°C to 50°C Nom. kWh 2.85 (6) 2.57 (6) 2.85 (6) 2.57 (6) 2.85 (6) 2.57 (6)
Heat up time from 10°C to 50°C hr 1h13min at 7°C ambient temperature 1h02min at 7°C ambient temperature 1h13min at 7°C ambient temperature 1h02min at 7°C ambient temperature 1h13min at 7°C ambient temperature 1h02min at 7°C ambient temperature
COP 4.66 (2) 4.66 (2) 5.00 (2) 5.00 (2) 5.00 (2) 5.00 (2)
Pump Type   Grundfos UPMXL GEO 25-125 130 PWM Grundfos UPMXL GEO 25-125 130 PWM Grundfos UPMXL GEO 25-125 130 PWM Grundfos UPMXL GEO 25-125 130 PWM Grundfos UPMXL GEO 25-125 130 PWM Grundfos UPMXL GEO 25-125 130 PWM
  Nominalna ESP jedinica Grijanje kPa 111.2 (7) 111.2 (7) 97.4 (7) 97.4 (7) 97.4 (7) 97.4 (7)
Izmjenjivač topline na vodenoj strani Količina vode u cirkulaciji Grijanje Nom. l/min 16.3 (2) 16.3 (2) 25.8 (2) 25.8 (2) 25.8 (2) 25.8 (2)
General Detalji o dobavljaču/proizvođaču Naziv ili adresa   Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
    Naziv ili trgovački znak   Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V.
  Product description Dizalica topline zrak-voda   Da Da Da Da Da Da
    Dizalica topline rasolina-u-vodu   Ne Ne Ne Ne Ne Ne
    Dizalica topline u kombinaciji s grijačem   Da Da Da Da Da Da
    Niskotemperaturna dizalica topline   Ne Ne Ne Ne Ne Ne
    Ugrađeni dodatni grijač   Da Da Da Da Da Da
    Dizalica topline voda-voda   Ne Ne Ne Ne Ne Ne
  LW(A) Sound power level (according to EN14825) Indoor dB(A) 44.0 44.0 44.0 44.0 44.0 44.0
LW(A) Razina zvučne snage (u skladu s EN14825) Vanjska dB(A) 54.0 54.0 54.0 54.0 54.0 54.0
Zvučna snaga u uvjetu Eko-dizajna i oznaka energetske učinkovitosti Zvučna snaga u režimu grijanja mjerena je prema EN12102 u uvjetima EN14825 Zvučna snaga u režimu grijanja mjerena je prema EN12102 u uvjetima EN14825 Zvučna snaga u režimu grijanja mjerena je prema EN12102 u uvjetima EN14825 Zvučna snaga u režimu grijanja mjerena je prema EN12102 u uvjetima EN14825 Zvučna snaga u režimu grijanja mjerena je prema EN12102 u uvjetima EN14825 Zvučna snaga u režimu grijanja mjerena je prema EN12102 u uvjetima EN14825
Tank Name   Spremnik tople vode od nehrđajućeg čelika od 230 litara Spremnik potrošne tople vode od nehrđajućeg čelika od 180 litara Spremnik tople vode od nehrđajućeg čelika od 230 litara Spremnik potrošne tople vode od nehrđajućeg čelika od 180 litara Spremnik tople vode od nehrđajućeg čelika od 230 litara Spremnik potrošne tople vode od nehrđajućeg čelika od 180 litara
Općenito grijanje prostora Zrak-voda jedinica Nazivni protok zraka (vanjska jedinica) m³/h   3,918   3,918   3,960
  Ostalo Regulacija učina   Inverter Inverter Inverter Inverter Inverter Inverter
    Pck (grijač kućišta kolj. osovine) kW 0.000 0.000 0.000 0.000 0.000 0.000
    Poff (režim isključeno) kW 0.031 0.031 0.031 0.031 0.031 0.031
    Psb (načina rada u stanju mirovanja) kW 0.042 0.042 0.042 0.042 0.042 0.042
    Pto (termostat isključen) kW 0.033 0.033 0.033 0.033 0.033 0.033
  Ugrađeni dodatni grijač Psup kW 6.0 6.0 6.0 6.0 6.0 6.0
    Vrsta ulazne energije   Električni Električni Električni Električni Električni Električni
Grijanje potrošne tople vode Općenito Deklarirani profil opterećenja   XL L XL L XL L
  Prosječni klimatski uvjeti AEC (godišnja potrošnja električne energije) kWh 1,572 969 1,572 969 1,572 969
    COPdhw   2.55 2.51 2.55 2.51 2.55 2.51
    Heat up time   1h 19min 1h 06min 1h 19min 1h 06min 1h 19min 1h 06min
    Ƞwh (učinkovitost grijanja vode) % 107 106 107 106 107 106
    Qelec (dnevna potrošnja električne energije) kWh 7.480 4.650 7.480 4.650 7.480 4.650
    Referentna temperatura potrošne tople vode °C 52.5 52.5 52.5 52.5 52.5 52.5
    Priključna snaga W 58.5 42.9 58.5 42.9 58.5 42.9
    Razred energetske učinkovitosti grijanja vode   A A A A A A
  Hladni klimatski uvjeti AEC (godišnja potrošnja električne energije) kWh 1,839 1,124 1,839 1,124 1,839 1,124
    COPdhw   2.19 2.17 2.19 2.17 2.19 2.17
    Heat up time   1h 16min 1h 04min 1h 16min 1h 04min 1h 16min 1h 04min
    Ƞwh (učinkovitost grijanja vode) % 91 91 91 91 91 91
    Qelec (dnevna potrošnja električne energije) kWh 8.720 5.370 8.720 5.370 8.720 5.370
    Referentna temperatura potrošne tople vode °C 52.5 52.5 52.5 52.5 52.5 52.5
    Priključna snaga W 63.7 45.0 63.7 45.0 63.7 45.0
  Topli klimatski uvjeti AEC (godišnja potrošnja električne energije) kWh 1,413 876 1,413 876 1,413 876
    COPdhw   2.83 2.76 2.83 2.76 2.83 2.76
    Heat up time   1h 30min 1h 15min 1h 30min 1h 15min 1h 30min 1h 15min
    Ƞwh (učinkovitost grijanja vode) % 119 117 119 117 119 117
    Qelec (dnevna potrošnja električne energije) kWh 6.740 4.220 6.740 4.220 6.740 4.220
    Referentna temperatura potrošne tople vode °C 52.5 52.5 52.5 52.5 52.5 52.5
    Priključna snaga W 55.4 41.6 55.4 41.6 55.4 41.6
Grijanje prostora Izlaz za vodu u prosječnoj klimi 55°C Općenito Godišnja potrošnja energije kWh 7,236 7,236 7,236 7,236 7,236 7,236
      Ƞs (sezonska učinkovitost grijanja prostora) % 140 140 140 140 140 140
      Pnazivno pri -10°C kW 13 13 13 13 13 13
      Qhe Godišnja potrošnja energije (GCV) Gj 26 26 26 26 26 26
      SCOP   3.57 3.57 3.57 3.57 3.57 3.57
      Razred sezonske učinkovitosti grijanja prostora   A++ A++ A++ A++ A++ A++
    Stanje (-7 °C DB/-8 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   2.43 2.43 2.43 2.43 2.43 2.43
      Pdh kW 11.1 11.1 11.1 11.1 11.1 11.1
      PERd % 97.2 97.2 97.2 97.2 97.2 97.2
    B Stanje (2 °C DB/1 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   3.52 3.52 3.52 3.52 3.52 3.52
      Pdh kW 6.7 6.7 6.7 6.7 6.7 6.7
      PERd % 140.8 140.8 140.8 140.8 140.8 140.8
    C Stanje (7 °C DB/6 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   4.54 4.54 4.54 4.54 4.54 4.54
      Pdh kW 6.5 6.5 6.5 6.5 6.5 6.5
      PERd % 181.6 181.6 181.6 181.6 181.6 181.6
    C Stanje (12 °C DB/11 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   5.97 5.97 5.97 5.97 5.97 5.97
      Pdh kW 5.2 5.2 5.2 5.2 5.2 5.2
      PERd % 238.8 238.8 238.8 238.8 238.8 238.8
    Tol (granična radna temperatura) COPd   2.12 2.12 2.12 2.12 2.12 2.12
      Pdh kW 12.5 12.5 12.5 12.5 12.5 12.5
      PERd % 84.8 84.8 84.8 84.8 84.8 84.8
      TOL °C -10 -10 -10 -10 -10 -10
      WTOL °C 55 55 55 55 55 55
    Dopunski toplinski učin na izlazu Psup (pri Tdesign -10°C) kW 0.0 0.0 0.0 0.0 0.0 0.0
    Tbiv (bivalentna temperatura) COPd   2.12 2.12 2.12 2.12 2.12 2.12
      Pdh kW 12.5 12.5 12.5 12.5 12.5 12.5
      PERd % 84.8 84.8 84.8 84.8 84.8 84.8
      Tbiv °C -10 -10 -10 -10 -10 -10
  Izlaz za vodu u hladnoj klimi 55°C Općenito Godišnja potrošnja energije kWh 9,658 9,658 9,658 9,658 9,658 9,658
      Ƞs (sezonska učinkovitost grijanja prostora) % 125 125 125 125 125 125
      Pnazivno pri -22°C kW 13 13 13 13 13 13
      Qhe Godišnja potrošnja energije (GCV) Gj 35 35 35 35 35 35
    Stanje (-7 °C DB/-8 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   2.74 2.74 2.74 2.74 2.74 2.74
      Pdh kW 7.5 7.5 7.5 7.5 7.5 7.5
      PERd % 109.6 109.6 109.6 109.6 109.6 109.6
    B Stanje (2 °C DB/1 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   3.67 3.67 3.67 3.67 3.67 3.67
      Pdh kW 5.8 5.8 5.8 5.8 5.8 5.8
      PERd % 146.8 146.8 146.8 146.8 146.8 146.8
    C Stanje (7 °C DB/6 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   4.69 4.69 4.69 4.69 4.69 4.69
      Pdh kW 5.6 5.6 5.6 5.6 5.6 5.6
      PERd % 187.6 187.6 187.6 187.6 187.6 187.6
    C Stanje (12 °C DB/11 °C WB) COPd   6.12 6.12 6.12 6.12 6.12 6.12
      Pdh kW 6.2 6.2 6.2 6.2 6.2 6.2
      PERd % 244.8 244.8 244.8 244.8 244.8 244.8
    Tol (granična radna temperatura) COPd   1.65 1.65 1.65 1.65 1.65 1.65
      Pdh kW 10.6 10.6 10.6 10.6 10.6 10.6
      PERd % 66.0 66.0 66.0 66.0 66.0 66.0
      TOL °C -22 -22 -22 -22 -22 -22
      WTOL °C 55 55 55 55 55 55
    G Stanje (-15°CDB/-) COPd   2.17 2.17 2.17 2.17 2.17 2.17
      Pdh kW 10.3 10.3 10.3 10.3 10.3 10.3
      PERd % 86.8 86.8 86.8 86.8 86.8 86.8
    Tbiv (bivalentna temperatura) COPd   1.90 1.90 1.90 1.90 1.90 1.90
      Pdh kW 11.0 11.0 11.0 11.0 11.0 11.0
      PERd % 76.0 76.0 76.0 76.0 76.0 76.0
      Tbiv °C -18 -18 -18 -18 -18 -18
    Dopunski toplinski učin na izlazu Psup (pri Tdesign -22°C) kW 1.9 1.9 1.9 1.9 1.9 1.9
  Izlaz za vodu u toploj klimi 55 °C Općenito Godišnja potrošnja energije kWh 4,063 4,063 4,063 4,063 4,063 4,063
      Ƞs (sezonska učinkovitost grijanja prostora) % 161 161 161 161 161 161
      Pnazivno pri 2°C kW 13 13 13 13 13 13
      Qhe Godišnja potrošnja energije (GCV) Gj 15 15 15 15 15 15
    B Stanje (2 °C DB/1 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   2.62 2.62 2.62 2.62 2.62 2.62
      Pdh kW 11.4 11.4 11.4 11.4 11.4 11.4
      PERd % 104.8 104.8 104.8 104.8 104.8 104.8
    C Stanje (7 °C DB/6 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   3.65 3.65 3.65 3.65 3.65 3.65
      Pdh kW 8.2 8.2 8.2 8.2 8.2 8.2
      PERd % 146.0 146.0 146.0 146.0 146.0 146.0
    C Stanje (12 °C DB/11 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   5.37 5.37 5.37 5.37 5.37 5.37
      Pdh kW 6.1 6.1 6.1 6.1 6.1 6.1
      PERd % 214.8 214.8 214.8 214.8 214.8 214.8
    Tbiv (bivalentna temperatura) COPd   3.18 3.18 3.18 3.18 3.18 3.18
      Pdh kW 11.0 11.0 11.0 11.0 11.0 11.0
      PERd % 127.2 127.2 127.2 127.2 127.2 127.2
      Tbiv °C 4 4 4 4 4 4
  Izlazna voda 45°C H uvjet (-2°C / - ) Maks. kW 11.1 11.1 11.8 11.8 11.8 11.8
  Izlaz za vodu u prosječnoj klimi 35°C Općenito SCOP   4.71 4.71 4.71 4.71 4.71 4.71
      Godišnja potrošnja energije kWh 5,479 5,479 5,479 5,479 5,479 5,479
      Ƞs (sezonska učinkovitost grijanja prostora) % 186 186 186 186 186 186
      Pnazivno pri -10°C kW 13 13 13 13 13 13
      Qhe Godišnja potrošnja energije (GCV) Gj 20 20 20 20 20 20
      Razred sezonske učinkovitosti grijanja prostora   A+++ A+++ A+++ A+++ A+++ A+++
    Stanje (-7 °C DB/-8 °C WB) COPd   2.97 2.97 2.97 2.97 2.97 2.97
      Pdh kW 10.7 10.7 10.7 10.7 10.7 10.7
      PERd % 118.8 118.8 118.8 118.8 118.8 118.8
    B Stanje (2 °C DB/1 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   4.94 4.94 4.94 4.94 4.94 4.94
      Pdh kW 6.9 6.9 6.9 6.9 6.9 6.9
      PERd % 197.6 197.6 197.6 197.6 197.6 197.6
    C Stanje (7 °C DB/6 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   5.95 5.95 5.95 5.95 5.95 5.95
      Pdh kW 6.2 6.2 6.2 6.2 6.2 6.2
      PERd % 238.0 238.0 238.0 238.0 238.0 238.0
    C Stanje (12 °C DB/11 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   7.07 7.07 7.07 7.07 7.07 7.07
      Pdh kW 5.6 5.6 5.6 5.6 5.6 5.6
      PERd % 282.8 282.8 282.8 282.8 282.8 282.8
    Tol (granična radna temperatura) COPd   2.88 2.88 2.88 2.88 2.88 2.88
      Pdh kW 12.1 12.1 12.1 12.1 12.1 12.1
      PERd % 115.2 115.2 115.2 115.2 115.2 115.2
      TOL °C -10 -10 -10 -10 -10 -10
      WTOL °C 35 35 35 35 35 35
    Tbiv (bivalentna temperatura) COPd   2.97 2.97 2.97 2.97 2.97 2.97
      Pdh kW 10.7 10.7 10.7 10.7 10.7 10.7
      PERd % 118.8 118.8 118.8 118.8 118.8 118.8
      Tbiv °C -7 -7 -7 -7 -7 -7
    Dopunski toplinski učin na izlazu Psup (pri Tdesign -10°C) kW 0.4 0.4 0.4 0.4 0.4 0.4
  Izlaz za vodu u hladnoj klimi 35 °C Općenito Godišnja potrošnja energije kWh 7,425 7,425 7,425 7,425 7,425 7,425
      Ƞs (sezonska učinkovitost grijanja prostora) % 163 163 163 163 163 163
      Pnazivno pri -22°C kW 13 13 13 13 13 13
      Qhe Godišnja potrošnja energije (GCV) Gj 27 27 27 27 27 27
    Stanje (-7 °C DB/-8 °C WB) COPd   3.50 3.50 3.50 3.50 3.50 3.50
      Pdh kW 8.0 8.0 8.0 8.0 8.0 8.0
      PERd % 140.0 140.0 140.0 140.0 140.0 140.0
    B Stanje (2 °C DB/1 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   5.07 5.07 5.07 5.07 5.07 5.07
      Pdh kW 4.9 4.9 4.9 4.9 4.9 4.9
      PERd % 202.8 202.8 202.8 202.8 202.8 202.8
    C Stanje (7 °C DB/6 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   6.10 6.10 6.10 6.10 6.10 6.10
      Pdh kW 5.3 5.3 5.3 5.3 5.3 5.3
      PERd % 244.0 244.0 244.0 244.0 244.0 244.0
    C Stanje (12 °C DB/11 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   7.03 7.03 7.03 7.03 7.03 7.03
      Pdh kW 5.7 5.7 5.7 5.7 5.7 5.7
      PERd % 281.2 281.2 281.2 281.2 281.2 281.2
    Tol (granična radna temperatura) COPd   2.16 2.16 2.16 2.16 2.16 2.16
      Pdh kW 10.1 10.1 10.1 10.1 10.1 10.1
      PERd % 86.4 86.4 86.4 86.4 86.4 86.4
      TOL °C -22 -22 -22 -22 -22 -22
      WTOL °C 35 35 35 35 35 35
    G Stanje (-15°CDB/-) COPd   2.62 2.62 2.62 2.62 2.62 2.62
      Pdh kW 10.7 10.7 10.7 10.7 10.7 10.7
      PERd % 104.8 104.8 104.8 104.8 104.8 104.8
    Tbiv (bivalentna temperatura) COPd   2.62 2.62 2.62 2.62 2.62 2.62
      Pdh kW 10.7 10.7 10.7 10.7 10.7 10.7
      PERd % 104.8 104.8 104.8 104.8 104.8 104.8
      Tbiv °C -15 -15 -15 -15 -15 -15
    Dopunski toplinski učin na izlazu Psup (pri Tdesign -22°C) kW 2.4 2.4 2.4 2.4 2.4 2.4
  Izlaz za vodu u toploj klimi 35°C Općenito Godišnja potrošnja energije kWh 2,992 2,992 2,992 2,992 2,992 2,992
      Ƞs (sezonska učinkovitost grijanja prostora) % 220 220 220 220 220 220
      Pnazivno pri 2°C kW 13 13 13 13 13 13
      Qhe Godišnja potrošnja energije (GCV) Gj 11 11 11 11 11 11
    B Stanje (2 °C DB/1 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   3.51 3.51 3.51 3.51 3.51 3.51
      Pdh kW 10.0 10.0 10.0 10.0 10.0 10.0
      PERd % 140.4 140.4 140.4 140.4 140.4 140.4
    C Stanje (7 °C DB/6 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   5.67 5.67 5.67 5.67 5.67 5.67
      Pdh kW 8.3 8.3 8.3 8.3 8.3 8.3
      PERd % 226.8 226.8 226.8 226.8 226.8 226.8
    Tbiv (bivalentna temperatura) COPd   4.96 4.96 4.96 4.96 4.96 4.96
      Pdh kW 9.8 9.8 9.8 9.8 9.8 9.8
      PERd % 198.4 198.4 198.4 198.4 198.4 198.4
      Tbiv °C 5 5 5 5 5 5
    C Stanje (12 °C DB/11 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   7.04 7.04 7.04 7.04 7.04 7.04
      Pdh kW 5.7 5.7 5.7 5.7 5.7 5.7
      PERd % 281.6 281.6 281.6 281.6 281.6 281.6
Napomene (1) - Učin je u skladu s normom EN14511 i valjan je za raspon grijane vode dT = 3~8°C at Ta 7°C (1) - Učin je u skladu s normom EN14511 i valjan je za raspon grijane vode dT = 3~8°C at Ta 7°C (1) - Učin je u skladu s normom EN14511 i valjan je za raspon grijane vode dT = 3~8°C at Ta 7°C (1) - Učin je u skladu s normom EN14511 i valjan je za raspon grijane vode dT = 3~8°C at Ta 7°C (1) - Učin je u skladu s normom EN14511 i valjan je za raspon grijane vode dT = 3~8°C at Ta 7°C (1) - Učin je u skladu s normom EN14511 i valjan je za raspon grijane vode dT = 3~8°C at Ta 7°C
  (2) - Uvjet: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Uvjet: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Uvjet: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Uvjet: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Uvjet: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Uvjet: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (3) - Hlađenje: EW 23°C; LW 18°C; uvjeti okoline: 35°CDB (3) - Hlađenje: EW 23°C; LW 18°C; uvjeti okoline: 35°CDB (3) - Hlađenje: EW 23°C; LW 18°C; uvjeti okoline: 35°CDB (3) - Hlađenje: EW 23°C; LW 18°C; uvjeti okoline: 35°CDB (3) - Hlađenje: EW 23°C; LW 18°C; uvjeti okoline: 35°CDB (3) - Hlađenje: EW 23°C; LW 18°C; uvjeti okoline: 35°CDB
  (4) - Hlađenje: EW 12°C; LW 7°C; uvjeti okoline: 35°CDB (4) - Hlađenje: EW 12°C; LW 7°C; uvjeti okoline: 35°CDB (4) - Hlađenje: EW 12°C; LW 7°C; uvjeti okoline: 35°CDB (4) - Hlađenje: EW 12°C; LW 7°C; uvjeti okoline: 35°CDB (4) - Hlađenje: EW 12°C; LW 7°C; uvjeti okoline: 35°CDB (4) - Hlađenje: EW 12°C; LW 7°C; uvjeti okoline: 35°CDB
  (5) - Ulazna snaga je ukupna snaga unutarnjih i vanjskih jedinica, uključujući cirkulacijsku crpku; u skladu s EN14511 (5) - Ulazna snaga je ukupna snaga unutarnjih i vanjskih jedinica, uključujući cirkulacijsku crpku; u skladu s EN14511 (5) - Ulazna snaga je ukupna snaga unutarnjih i vanjskih jedinica, uključujući cirkulacijsku crpku; u skladu s EN14511 (5) - Ulazna snaga je ukupna snaga unutarnjih i vanjskih jedinica, uključujući cirkulacijsku crpku; u skladu s EN14511 (5) - Ulazna snaga je ukupna snaga unutarnjih i vanjskih jedinica, uključujući cirkulacijsku crpku; u skladu s EN14511 (5) - Ulazna snaga je ukupna snaga unutarnjih i vanjskih jedinica, uključujući cirkulacijsku crpku; u skladu s EN14511
  (6) - Ispitano pri Ta DB/WB 7 °C/6 °C prema EN 16147. (6) - Ispitano pri Ta DB/WB 7 °C/6 °C prema EN 16147. (6) - Ispitano pri Ta DB/WB 7 °C/6 °C prema EN 16147. (6) - Ispitano pri Ta DB/WB 7 °C/6 °C prema EN 16147. (6) - Ispitano pri Ta DB/WB 7 °C/6 °C prema EN 16147. (6) - Ispitano pri Ta DB/WB 7 °C/6 °C prema EN 16147.
  (7) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C), s pumpom na punoj brzini (7) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C), s pumpom na punoj brzini (7) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C), s pumpom na punoj brzini (7) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C), s pumpom na punoj brzini (7) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C), s pumpom na punoj brzini (7) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C), s pumpom na punoj brzini