Tablica podataka za ETSHB-D / EPRA014-018DW

ETSHB16P30DA / EPRA14DAW1 ETSHB16P50DA / EPRA14DAW1 ETSHB16P30DA / EPRA16DAW1 ETSHB16P50DA / EPRA16DAW1 ETSHB16P30DA / EPRA18DAW1 ETSHB16P50DA / EPRA18DAW1
Indoor unit ETSHB16P30DA ETSHB16P50DA ETSHB16P30DA ETSHB16P50DA ETSHB16P30DA ETSHB16P50DA
Outdoor unit EPRA14DAW1 EPRA14DAW1 EPRA16DAW1 EPRA16DAW1 EPRA18DAW1 EPRA18DAW1
Učin grijanja Nom. kW 5.69 (1) 5.69 (1) 9.00 (1) 9.00 (1) 9.00 (1) 9.00 (1)
Ulazna struja Grijanje Nom. kW 1.22 (1) 1.22 (1) 1.80 (1) 1.80 (1) 1.80 (1) 1.80 (1)
  Domestic hot water from 10°C to 50°C Nom. kWh 3.50 4.98 3.50 4.98 3.50 4.98
Heat up time from 10°C to 50°C hr 1h25min at 7°C ambient temperature 1h46min at 7°C ambient temperature 1h25min at 7°C ambient temperature 1h46min at 7°C ambient temperature 1h25min at 7°C ambient temperature 1h46min at 7°C ambient temperature
COP 4.66 (1) 4.66 (1) 5.00 (1) 5.00 (1) 5.00 (1) 5.00 (1)
Pump Type   Grundfos UPMXL 20-125 CHBL PWM RT Grundfos UPMXL 20-125 CHBL PWM RT Grundfos UPMXL 20-125 CHBL PWM RT Grundfos UPMXL 20-125 CHBL PWM RT Grundfos UPMXL 20-125 CHBL PWM RT Grundfos UPMXL 20-125 CHBL PWM RT
Izmjenjivač topline na vodenoj strani Količina vode u cirkulaciji Grijanje Nom. l/min 16.3 (1) 16.3 (1) 25.8 (1) 25.8 (1) 25.8 (1) 25.8 (1)
General Detalji o dobavljaču/proizvođaču Naziv ili adresa   Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
    Naziv ili trgovački znak   Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V.
  Product description Dizalica topline zrak-voda   Da Da Da Da Da Da
    Dizalica topline rasolina-u-vodu   Ne Ne Ne Ne Ne Ne
    Dizalica topline u kombinaciji s grijačem   Da Da Da Da Da Da
    Niskotemperaturna dizalica topline   Ne Ne Ne Ne Ne Ne
    Ugrađeni dodatni grijač   Ne Ne Ne Ne Ne Ne
    Dizalica topline voda-voda   Ne Ne Ne Ne Ne Ne
  LW(A) Sound power level (according to EN14825) Indoor dB(A) 45.6 45.6 45.6 45.6 45.6 45.6
LW(A) Razina zvučne snage (u skladu s EN14825) Vanjska dB(A) 54.0 54.0 54.0 54.0 54.0 54.0
Zvučna snaga u uvjetu Eko-dizajna i oznaka energetske učinkovitosti Zvučna snaga u režimu grijanja mjerena je prema EN12102 u uvjetima EN14825 Zvučna snaga u režimu grijanja mjerena je prema EN12102 u uvjetima EN14825 Zvučna snaga u režimu grijanja mjerena je prema EN12102 u uvjetima EN14825 Zvučna snaga u režimu grijanja mjerena je prema EN12102 u uvjetima EN14825 Zvučna snaga u režimu grijanja mjerena je prema EN12102 u uvjetima EN14825 Zvučna snaga u režimu grijanja mjerena je prema EN12102 u uvjetima EN14825
Općenito grijanje prostora Zrak-voda jedinica Nazivni protok zraka (vanjska jedinica) m³/h 3,918 3,918 3,918 3,918 3,960 3,960
  Ostalo Regulacija učina   Inverter Inverter Inverter Inverter Inverter Inverter
    Poff (režim isključeno) kW 0.031 0.031 0.031 0.031 0.031 0.031
    Psb (načina rada u stanju mirovanja) kW 0.042 0.042 0.042 0.042 0.042 0.042
    Pto (termostat isključen) kW 0.033 0.033 0.033 0.033 0.033 0.033
  Ugrađeni dodatni grijač Vrsta ulazne energije   Električni Električni Električni Električni Električni Električni
Grijanje potrošne tople vode Općenito Deklarirani profil opterećenja   L XL L XL L XL
    Funkcija za utvrđivanje grijanja vode tijekom sati jeftinije električne energije   Da Da Da Da Da Da
  Prosječni klimatski uvjeti AEC (godišnja potrošnja električne energije) kWh 1,017 1,451 1,017 1,451 1,017 1,451
    COPdhw   2.38 2.75 2.38 2.75 2.38 2.75
    Mješanje vode na 40°C l 149.0 215.7 149.0 215.7 149.0 215.7
    Ƞwh (učinkovitost grijanja vode) % 101 115 101 115 101 115
    Qelec (dnevna potrošnja električne energije) kWh 4.904 6.924 4.904 6.924 4.904 6.924
    Referentna temperatura potrošne tople vode °C 47.0 47.0 47.0 47.0 47.0 47.0
    Priključna snaga W 49.0 57.1 49.0 57.1 49.0 57.1
    Razred energetske učinkovitosti grijanja vode   A A A A A A
  Hladni klimatski uvjeti AEC (godišnja potrošnja električne energije) kWh 1,136 1,655 1,136 1,655 1,136 1,655
    COPdhw   2.13 2.43 2.13 2.43 2.13 2.43
    Mješanje vode na 40°C l 149.0 215.7 149.0 215.7 149.0 215.7
    Ƞwh (učinkovitost grijanja vode) % 90 101 90 101 90 101
    Qelec (dnevna potrošnja električne energije) kWh 5.476 7.851 5.476 7.851 5.476 7.851
    Referentna temperatura potrošne tople vode °C 47.0 47.0 47.0 47.0 47.0 47.0
  Topli klimatski uvjeti AEC (godišnja potrošnja električne energije) kWh 891 1,306 891 1,306 891 1,306
    COPdhw   2.69 3.04 2.69 3.04 2.69 3.04
    Miješana voda na 40°C l 149.0 215.7 149.0 215.7 149.0 215.7
    Ƞwh (učinkovitost grijanja vode) % 115 128 115 128 115 128
    Qelec (dnevna potrošnja električne energije) kWh 4.330 6.263 4.330 6.263 4.330 6.263
    Referentna temperatura potrošne tople vode °C 47.0 47.0 47.0 47.0 47.0 47.0
Grijanje prostora Izlaz za vodu u prosječnoj klimi 55°C Općenito Godišnja potrošnja energije kWh 7,236 7,236 7,236 7,236 7,236 7,236
      Ƞs (sezonska učinkovitost grijanja prostora) % 140 140 140 140 140 140
      Pnazivno pri -10°C kW 13 13 13 13 13 13
      Qhe Godišnja potrošnja energije (GCV) Gj 26 26 26 26 26 26
      SCOP   3.57 3.57 3.57 3.57 3.57 3.57
      Razred sezonske učinkovitosti grijanja prostora   A++ A++ A++ A++ A++ A++
    Stanje (-7 °C DB/-8 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   2.43 2.43 2.43 2.43 2.43 2.43
      Pdh kW 11.1 11.1 11.1 11.1 11.1 11.1
      PERd % 97.2 97.2 97.2 97.2 97.2 97.2
    B Stanje (2 °C DB/1 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   3.52 3.52 3.52 3.52 3.52 3.52
      Pdh kW 6.7 6.7 6.7 6.7 6.7 6.7
      PERd % 140.8 140.8 140.8 140.8 140.8 140.8
    C Stanje (7 °C DB/6 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   4.54 4.54 4.54 4.54 4.54 4.54
      Pdh kW 6.5 6.5 6.5 6.5 6.5 6.5
      PERd % 181.6 181.6 181.6 181.6 181.6 181.6
    C Stanje (12 °C DB/11 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   5.97 5.97 5.97 5.97 5.97 5.97
      Pdh kW 5.2 5.2 5.2 5.2 5.2 5.2
      PERd % 238.8 238.8 238.8 238.8 238.8 238.8
    Tol (granična radna temperatura) COPd   2.12 2.12 2.12 2.12 2.12 2.12
      Pdh kW 12.5 12.5 12.5 12.5 12.5 12.5
      PERd % 84.8 84.8 84.8 84.8 84.8 84.8
      TOL °C -10 -10 -10 -10 -10 -10
      WTOL °C 55 55 55 55 55 55
    Dopunski toplinski učin na izlazu Psup (pri Tdesign -10°C) kW 0.0 0.0 0.0 0.0 0.0 0.0
    Tbiv (bivalentna temperatura) COPd   2.12 2.12 2.12 2.12 2.12 2.12
      Pdh kW 12.5 12.5 12.5 12.5 12.5 12.5
      PERd % 84.8 84.8 84.8 84.8 84.8 84.8
      Tbiv °C -10 -10 -10 -10 -10 -10
  Izlaz za vodu u hladnoj klimi 55°C Općenito Godišnja potrošnja energije kWh 9,658 9,658 9,658 9,658 9,658 9,658
      Ƞs (sezonska učinkovitost grijanja prostora) % 125 125 125 125 125 125
      Pnazivno pri -22°C kW 13 13 13 13 13 13
      Qhe Godišnja potrošnja energije (GCV) Gj 35 35 35 35 35 35
    Stanje (-7 °C DB/-8 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   2.74 2.74 2.74 2.74 2.74 2.74
      Pdh kW 7.5 7.5 7.5 7.5 7.5 7.5
      PERd % 109.6 109.6 109.6 109.6 109.6 109.6
    B Stanje (2 °C DB/1 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   3.67 3.67 3.67 3.67 3.67 3.67
      Pdh kW 5.8 5.8 5.8 5.8 5.8 5.8
      PERd % 146.8 146.8 146.8 146.8 146.8 146.8
    C Stanje (7 °C DB/6 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   4.69 4.69 4.69 4.69 4.69 4.69
      Pdh kW 5.6 5.6 5.6 5.6 5.6 5.6
      PERd % 187.6 187.6 187.6 187.6 187.6 187.6
    C Stanje (12 °C DB/11 °C WB) COPd   6.12 6.12 6.12 6.12 6.12 6.12
      Pdh kW 6.2 6.2 6.2 6.2 6.2 6.2
      PERd % 244.8 244.8 244.8 244.8 244.8 244.8
    Tol (granična radna temperatura) COPd   1.65 1.65 1.65 1.65 1.65 1.65
      Pdh kW 10.6 10.6 10.6 10.6 10.6 10.6
      PERd % 66.0 66.0 66.0 66.0 66.0 66.0
      TOL °C -22 -22 -22 -22 -22 -22
      WTOL °C 55 55 55 55 55 55
    G Stanje (-15°CDB/-) COPd   2.17 2.17 2.17 2.17 2.17 2.17
      Pdh kW 10.3 10.3 10.3 10.3 10.3 10.3
      PERd % 86.8 86.8 86.8 86.8 86.8 86.8
    Tbiv (bivalentna temperatura) COPd   1.90 1.90 1.90 1.90 1.90 1.90
      Pdh kW 11.0 11.0 11.0 11.0 11.0 11.0
      PERd % 76.0 76.0 76.0 76.0 76.0 76.0
      Tbiv °C -18 -18 -18 -18 -18 -18
    Dopunski toplinski učin na izlazu Psup (pri Tdesign -22°C) kW 1.9 1.9 1.9 1.9 1.9 1.9
  Izlaz za vodu u toploj klimi 55 °C Općenito Godišnja potrošnja energije kWh 4,063 4,063 4,063 4,063 4,063 4,063
      Ƞs (sezonska učinkovitost grijanja prostora) % 161 161 161 161 161 161
      Pnazivno pri 2°C kW 13 13 13 13 13 13
      Qhe Godišnja potrošnja energije (GCV) Gj 15 15 15 15 15 15
    B Stanje (2 °C DB/1 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   2.62 2.62 2.62 2.62 2.62 2.62
      Pdh kW 11.4 11.4 11.4 11.4 11.4 11.4
      PERd % 104.8 104.8 104.8 104.8 104.8 104.8
    C Stanje (7 °C DB/6 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   3.65 3.65 3.65 3.65 3.65 3.65
      Pdh kW 8.2 8.2 8.2 8.2 8.2 8.2
      PERd % 146.0 146.0 146.0 146.0 146.0 146.0
    C Stanje (12 °C DB/11 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   5.37 5.37 5.37 5.37 5.37 5.37
      Pdh kW 6.1 6.1 6.1 6.1 6.1 6.1
      PERd % 214.8 214.8 214.8 214.8 214.8 214.8
    Tbiv (bivalentna temperatura) COPd   3.18 3.18 3.18 3.18 3.18 3.18
      Pdh kW 11.0 11.0 11.0 11.0 11.0 11.0
      PERd % 127.2 127.2 127.2 127.2 127.2 127.2
      Tbiv °C 4 4 4 4 4 4
  Izlazna voda 45°C H uvjet (-2°C / - ) Maks. kW 11.1 11.1 11.8 11.8 11.8 11.8
  Izlaz za vodu u prosječnoj klimi 35°C Općenito SCOP   4.71 4.71 4.71 4.71 4.71 4.71
      Godišnja potrošnja energije kWh 5,479 5,479 5,479 5,479 5,479 5,479
      Ƞs (sezonska učinkovitost grijanja prostora) % 186 186 186 186 186 186
      Pnazivno pri -10°C kW 13 13 13 13 13 13
      Qhe Godišnja potrošnja energije (GCV) Gj 20 20 20 20 20 20
      Razred sezonske učinkovitosti grijanja prostora   A+++ A+++ A+++ A+++ A+++ A+++
    Stanje (-7 °C DB/-8 °C WB) COPd   2.97 2.97 2.97 2.97 2.97 2.97
      Pdh kW 10.7 10.7 10.7 10.7 10.7 10.7
      PERd % 118.8 118.8 118.8 118.8 118.8 118.8
    B Stanje (2 °C DB/1 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   4.94 4.94 4.94 4.94 4.94 4.94
      Pdh kW 6.9 6.9 6.9 6.9 6.9 6.9
      PERd % 197.6 197.6 197.6 197.6 197.6 197.6
    C Stanje (7 °C DB/6 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   5.95 5.95 5.95 5.95 5.95 5.95
      Pdh kW 6.2 6.2 6.2 6.2 6.2 6.2
      PERd % 238.0 238.0 238.0 238.0 238.0 238.0
    C Stanje (12 °C DB/11 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   7.07 7.07 7.07 7.07 7.07 7.07
      Pdh kW 5.6 5.6 5.6 5.6 5.6 5.6
      PERd % 282.8 282.8 282.8 282.8 282.8 282.8
    Tol (granična radna temperatura) COPd   2.88 2.88 2.88 2.88 2.88 2.88
      Pdh kW 12.1 12.1 12.1 12.1 12.1 12.1
      PERd % 115.2 115.2 115.2 115.2 115.2 115.2
      TOL °C -10 -10 -10 -10 -10 -10
      WTOL °C 35 35 35 35 35 35
    Tbiv (bivalentna temperatura) COPd   2.97 2.97 2.97 2.97 2.97 2.97
      Pdh kW 10.7 10.7 10.7 10.7 10.7 10.7
      PERd % 118.8 118.8 118.8 118.8 118.8 118.8
      Tbiv °C -7 -7 -7 -7 -7 -7
    Dopunski toplinski učin na izlazu Psup (pri Tdesign -10°C) kW 0.4 0.4 0.4 0.4 0.4 0.4
  Izlaz za vodu u hladnoj klimi 35 °C Općenito Godišnja potrošnja energije kWh 7,425 7,425 7,425 7,425 7,425 7,425
      Ƞs (sezonska učinkovitost grijanja prostora) % 163 163 163 163 163 163
      Pnazivno pri -22°C kW 13 13 13 13 13 13
      Qhe Godišnja potrošnja energije (GCV) Gj 27 27 27 27 27 27
    Stanje (-7 °C DB/-8 °C WB) COPd   3.50 3.50 3.50 3.50 3.50 3.50
      Pdh kW 8.0 8.0 8.0 8.0 8.0 8.0
      PERd % 140.0 140.0 140.0 140.0 140.0 140.0
    B Stanje (2 °C DB/1 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   5.07 5.07 5.07 5.07 5.07 5.07
      Pdh kW 4.9 4.9 4.9 4.9 4.9 4.9
      PERd % 202.8 202.8 202.8 202.8 202.8 202.8
    C Stanje (7 °C DB/6 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   6.10 6.10 6.10 6.10 6.10 6.10
      Pdh kW 5.3 5.3 5.3 5.3 5.3 5.3
      PERd % 244.0 244.0 244.0 244.0 244.0 244.0
    C Stanje (12 °C DB/11 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   7.03 7.03 7.03 7.03 7.03 7.03
      Pdh kW 5.7 5.7 5.7 5.7 5.7 5.7
      PERd % 281.2 281.2 281.2 281.2 281.2 281.2
    Tol (granična radna temperatura) COPd   2.16 2.16 2.16 2.16 2.16 2.16
      Pdh kW 10.1 10.1 10.1 10.1 10.1 10.1
      PERd % 86.4 86.4 86.4 86.4 86.4 86.4
      TOL °C -22 -22 -22 -22 -22 -22
      WTOL °C 35 35 35 35 35 35
    G Stanje (-15°CDB/-) COPd   2.62 2.62 2.62 2.62 2.62 2.62
      Pdh kW 10.7 10.7 10.7 10.7 10.7 10.7
      PERd % 104.8 104.8 104.8 104.8 104.8 104.8
    Tbiv (bivalentna temperatura) COPd   2.62 2.62 2.62 2.62 2.62 2.62
      Pdh kW 10.7 10.7 10.7 10.7 10.7 10.7
      PERd % 104.8 104.8 104.8 104.8 104.8 104.8
      Tbiv °C -15 -15 -15 -15 -15 -15
    Dopunski toplinski učin na izlazu Psup (pri Tdesign -22°C) kW 2.4 2.4 2.4 2.4 2.4 2.4
  Izlaz za vodu u toploj klimi 35°C Općenito Godišnja potrošnja energije kWh 2,992 2,992 2,992 2,992 2,992 2,992
      Ƞs (sezonska učinkovitost grijanja prostora) % 220 220 220 220 220 220
      Pnazivno pri 2°C kW 13 13 13 13 13 13
      Qhe Godišnja potrošnja energije (GCV) Gj 11 11 11 11 11 11
    B Stanje (2 °C DB/1 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   3.51 3.51 3.51 3.51 3.51 3.51
      Pdh kW 10.0 10.0 10.0 10.0 10.0 10.0
      PERd % 140.4 140.4 140.4 140.4 140.4 140.4
    C Stanje (7 °C DB/6 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   5.67 5.67 5.67 5.67 5.67 5.67
      Pdh kW 8.3 8.3 8.3 8.3 8.3 8.3
      PERd % 226.8 226.8 226.8 226.8 226.8 226.8
    Tbiv (bivalentna temperatura) COPd   4.96 4.96 4.96 4.96 4.96 4.96
      Pdh kW 9.8 9.8 9.8 9.8 9.8 9.8
      PERd % 198.4 198.4 198.4 198.4 198.4 198.4
      Tbiv °C 5 5 5 5 5 5
    C Stanje (12 °C DB/11 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   7.04 7.04 7.04 7.04 7.04 7.04
      Pdh kW 5.7 5.7 5.7 5.7 5.7 5.7
      PERd % 281.6 281.6 281.6 281.6 281.6 281.6
Napomene (1) - Uvjet: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Uvjet: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Uvjet: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Uvjet: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Uvjet: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Uvjet: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (2) - Hlađenje: EW 23°C; LW 18°C; uvjeti okoline: 35°CDB (2) - Hlađenje: EW 23°C; LW 18°C; uvjeti okoline: 35°CDB (2) - Hlađenje: EW 23°C; LW 18°C; uvjeti okoline: 35°CDB (2) - Hlađenje: EW 23°C; LW 18°C; uvjeti okoline: 35°CDB (2) - Hlađenje: EW 23°C; LW 18°C; uvjeti okoline: 35°CDB (2) - Hlađenje: EW 23°C; LW 18°C; uvjeti okoline: 35°CDB
  (3) - Hlađenje: EW 12°C; LW 7°C; uvjeti okoline: 35°CDB (3) - Hlađenje: EW 12°C; LW 7°C; uvjeti okoline: 35°CDB (3) - Hlađenje: EW 12°C; LW 7°C; uvjeti okoline: 35°CDB (3) - Hlađenje: EW 12°C; LW 7°C; uvjeti okoline: 35°CDB (3) - Hlađenje: EW 12°C; LW 7°C; uvjeti okoline: 35°CDB (3) - Hlađenje: EW 12°C; LW 7°C; uvjeti okoline: 35°CDB