Specifications Table for ETSH-D / EPRA014-018DV

ETSH16P30DA / EPRA14DAV3 ETSH16P50DA / EPRA14DAV3 ETSH16P50DA / EPRA16DAV3 ETSH16P30DA / EPRA16DAV3 ETSH16P50DA / EPRA18DAV3 ETSH16P30DA / EPRA18DAV3
Indoor unit ETSH16P30DA ETSH16P50DA ETSH16P50DA ETSH16P30DA ETSH16P50DA ETSH16P30DA
Outdoor unit EPRA14DAV3 EPRA14DAV3 EPRA16DAV3 EPRA16DAV3 EPRA18DAV3 EPRA18DAV3
Učin grijanja Nom. kW 5.69 (1) 5.69 (1) 9.00 (1) 9.00 (1) 9.00 (1) 9.00 (1)
Ulazna snaga Grijanje Nom. kW 1.22 (1) 1.22 (1) 1.80 (1) 1.80 (1) 1.80 (1) 1.80 (1)
  Potrošna topla voda od 10°C do 50 °C Nom. kWh 3.92 5.78 5.78 3.92 5.78 3.92
Heat up time from 10°C to 50°C hr 1h41min at 7°C ambient temperature 2h18min at 7°C ambient temperature 2h18min at 7°C ambient temperature 1h41min at 7°C ambient temperature 2h18min at 7°C ambient temperature 1h41min at 7°C ambient temperature
COP 4.67 (1) 4.67 (1) 5.00 (1) 5.00 (1) 5.00 (1) 5.00 (1)
Pumpa Type   Grundfos UPMXL 20-125 CHBL PWM RT Grundfos UPMXL 20-125 CHBL PWM RT Grundfos UPMXL 20-125 CHBL PWM RT Grundfos UPMXL 20-125 CHBL PWM RT Grundfos UPMXL 20-125 CHBL PWM RT Grundfos UPMXL 20-125 CHBL PWM RT
Izmjenjivač topline na vodenoj strani Količina vode u cirkulaciji Grijanje Nom. l/min 16.3 (1) 16.3 (1) 25.8 (1) 25.8 (1) 25.8 (1) 25.8 (1)
Općenito Detalji o dobavljaču/proizvođaču Name and address   Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
    Naziv ili trgovački znak   Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V.
  Opis proizvoda Dizalica topline zrak-voda   Da Da Da Da Da Da
    Dizalica topline rasolina-u-vodu   Ne Ne Ne Ne Ne Ne
    Dizalica topline u kombinaciji s grijačem   Da Da Da Da Da Da
    Niskotemperaturna dizalica topline   Ne Ne Ne Ne Ne Ne
    Ugrađeni dodatni grijač   Ne Ne Ne Ne Ne Ne
    Dizalica topline voda-voda   Ne Ne Ne Ne Ne Ne
  LW(A) Razina zvučne snage (u skladu s EN14825) Unutarnja dB(A) 45.6 45.6 45.6 45.6 45.6 45.6
LW(A) Razina zvučne snage (u skladu s EN14825) Vanjska dB(A) 54.0 54.0 54.0 54.0 54.0 54.0
Zvučna snaga u uvjetu Eko-dizajna i oznaka energetske učinkovitosti Zvučna snaga u režimu grijanja mjerena je prema EN12102 u uvjetima EN14825 Zvučna snaga u režimu grijanja mjerena je prema EN12102 u uvjetima EN14825 Zvučna snaga u režimu grijanja mjerena je prema EN12102 u uvjetima EN14825 Zvučna snaga u režimu grijanja mjerena je prema EN12102 u uvjetima EN14825 Zvučna snaga u režimu grijanja mjerena je prema EN12102 u uvjetima EN14825 Zvučna snaga u režimu grijanja mjerena je prema EN12102 u uvjetima EN14825
Općenito grijanje prostora Zrak-voda jedinica Nazivni protok zraka (vanjska jedinica) m³/h 3,918 3,918 3,918 3,918 3,960 3,960
  Ostalo Regulacija učina   Inverter Inverter Inverter Inverter Inverter Inverter
    Poff (režim isključeno) kW 0.021 0.021 0.021 0.021 0.021 0.021
    Psb (načina rada u stanju mirovanja) kW 0.021 0.021 0.021 0.021 0.021 0.021
    Pto (termostat isključen) kW 0.041 0.041 0.041 0.041 0.041 0.041
  Ugrađeni dodatni grijač Vrsta ulazne energije   Električni Električni Električni Električni Električni Električni
Grijanje potrošne tople vode Općenito Deklarirani profil opterećenja   L XL XL L XL L
    Funkcija za utvrđivanje grijanja vode tijekom sati jeftinije električne energije   Da Da Da Da Da Da
  Prosječni klimatski uvjeti AEC (godišnja potrošnja električne energije) kWh 1,017 1,459 1,459 1,017 1,459 1,017
    Domestic hot water heating-=-Average climate-=-COPdhw   2.38 2.75 2.75 2.38 2.75 2.38
    Domestic hot water heating-=-Average climate-=-Mixed water at 40°C-=-l l 149.0 237.2 237.2 149.0 237.2 149.0
    Ƞwh (water heating efficiency) % 101 115 115 101 115 101
    Qelec (dnevna potrošnja električne energije) kWh 4.900 6.924 6.924 4.900 6.924 4.900
    Domestic hot water heating-=-Average climate-=-Reference hot water temperature-=-°C °C 47.0 47.0 47.0 47.0 47.0 47.0
    Domestic hot water heating-=-Average climate-=-Stand-by power input-=-W W 49.0 51.0 51.0 49.0 51.0 49.0
    Razred energetske učinkovitosti grijanja vode   A A A A A A
  Hladni klimatski uvjeti AEC (godišnja potrošnja električne energije) kWh 1,143 1,669 1,669 1,143 1,669 1,143
    Domestic hot water heating-=-Cold climate-=-COPdhw   2.12 2.41 2.41 2.12 2.41 2.12
    Domestic hot water heating-=-Cold climate-=-Mixed water at 40°C-=-l l 149.0 237.2 237.2 149.0 237.2 149.0
    Ƞwh (učinkovitost grijanja vode) % 90 100 100 90 100 90
    Qelec (dnevna potrošnja električne energije) kWh 5.506 7.902 7.902 5.506 7.902 5.506
    Domestic hot water heating-=-Cold climate-=-Reference hot water temperature-=-°C °C 47.0 47.0 47.0 47.0 47.0 47.0
  Topli klimatski uvjeti AEC (godišnja potrošnja električne energije) kWh 902 1,430 1,430 902 1,430 902
    Domestic hot water heating-=-Warm climate-=-COPdhw   2.67 2.81 2.81 2.67 2.81 2.67
    Domestic hot water heating-=-Warm climate-=-Mixed water at 40°C-=-l l 149.0 237.2 237.2 149.0 237.2 149.0
    Ƞwh (učinkovitost grijanja vode) % 114 117 117 114 117 114
    Qelec (dnevna potrošnja električne energije) kWh 4.377 6.794 6.794 4.377 6.794 4.377
    Domestic hot water heating-=-Warm climate-=-Reference hot water temperature-=-°C °C 47.0 47.0 47.0 47.0 47.0 47.0
Grijanje prostora Izlaz za vodu u prosječnoj klimi 55°C Općenito Godišnja potrošnja energije kWh 7,211 7,211 7,211 7,211 7,211 7,211
      Ƞs (sezonska učinkovitost grijanja prostora) % 140 140 140 140 140 140
      Pnazivno pri -10°C kW 13 13 13 13 13 13
      Qhe Godišnja potrošnja energije (GCV) Gj 26 26 26 26 26 26
      SCOP   3.58 3.58 3.58 3.58 3.58 3.58
      Razred sezonske učinkovitosti grijanja prostora   A++ A++ A++ A++ A++ A++
    Stanje (-7 °C DB/-8 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   2.47 2.47 2.47 2.47 2.47 2.47
      Pdh kW 11.2 11.2 11.2 11.2 11.2 11.2
      PERd % 98.8 98.8 98.8 98.8 98.8 98.8
    B Stanje (2 °C DB/1 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   3.56 3.56 3.56 3.56 3.56 3.56
      Pdh kW 6.9 6.9 6.9 6.9 6.9 6.9
      PERd % 142.4 142.4 142.4 142.4 142.4 142.4
    C Stanje (7 °C DB/6 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   4.44 4.44 4.44 4.44 4.44 4.44
      Pdh kW 6.9 6.9 6.9 6.9 6.9 6.9
      PERd % 177.6 177.6 177.6 177.6 177.6 177.6
    C Stanje (12 °C DB/11 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   5.72 5.72 5.72 5.72 5.72 5.72
      Pdh kW 6.2 6.2 6.2 6.2 6.2 6.2
      PERd % 228.8 228.8 228.8 228.8 228.8 228.8
    Tol (granična radna temperatura) COPd   2.19 2.19 2.19 2.19 2.19 2.19
      Pdh kW 12.2 12.2 12.2 12.2 12.2 12.2
      PERd % 87.6 87.6 87.6 87.6 87.6 87.6
      TOL °C -10 -10 -10 -10 -10 -10
      WTOL °C 55 55 55 55 55 55
    Dopunski toplinski učin na izlazu Psup (pri Tdesign -10°C) kW 0.3 0.3 0.3 0.3 0.3 0.3
    Tbiv (bivalentna temperatura) COPd   2.19 2.19 2.19 2.19 2.19 2.19
      Pdh kW 12.2 12.2 12.2 12.2 12.2 12.2
      PERd % 87.6 87.6 87.6 87.6 87.6 87.6
      Tbiv °C -10 -10 -10 -10 -10 -10
  Izlaz za vodu u hladnoj klimi 55°C Općenito Godišnja potrošnja energije kWh 9,654 9,654 9,654 9,654 9,654 9,654
      Ƞs (sezonska učinkovitost grijanja prostora) % 125 125 125 125 125 125
      Pnazivno pri -22°C kW 13 13 13 13 13 13
      Qhe Godišnja potrošnja energije (GCV) Gj 35 35 35 35 35 35
    Stanje (-7 °C DB/-8 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   2.74 2.74 2.74 2.74 2.74 2.74
      Pdh kW 7.5 7.5 7.5 7.5 7.5 7.5
      PERd % 109.6 109.6 109.6 109.6 109.6 109.6
    B Stanje (2 °C DB/1 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   3.67 3.67 3.67 3.67 3.67 3.67
      Pdh kW 5.8 5.8 5.8 5.8 5.8 5.8
      PERd % 146.8 146.8 146.8 146.8 146.8 146.8
    C Stanje (7 °C DB/6 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   4.69 4.69 4.69 4.69 4.69 4.69
      Pdh kW 5.6 5.6 5.6 5.6 5.6 5.6
      PERd % 187.6 187.6 187.6 187.6 187.6 187.6
    C Stanje (12 °C DB/11 °C WB) COPd   6.12 6.12 6.12 6.12 6.12 6.12
      Pdh kW 6.2 6.2 6.2 6.2 6.2 6.2
      PERd % 244.8 244.8 244.8 244.8 244.8 244.8
    Tol (granična radna temperatura) COPd   1.65 1.65 1.65 1.65 1.65 1.65
      Pdh kW 10.6 10.6 10.6 10.6 10.6 10.6
      PERd % 66.0 66.0 66.0 66.0 66.0 66.0
      TOL °C -22 -22 -22 -22 -22 -22
      WTOL °C 55 55 55 55 55 55
    G Stanje (-15°CDB/-) COPd   2.17 2.17 2.17 2.17 2.17 2.17
      Pdh kW 10.3 10.3 10.3 10.3 10.3 10.3
      PERd % 86.8 86.8 86.8 86.8 86.8 86.8
    Tbiv (bivalentna temperatura) COPd   1.90 1.90 1.90 1.90 1.90 1.90
      Pdh kW 11.0 11.0 11.0 11.0 11.0 11.0
      PERd % 76.0 76.0 76.0 76.0 76.0 76.0
      Tbiv °C -18 -18 -18 -18 -18 -18
    Dopunski toplinski učin na izlazu Psup (pri Tdesign -22°C) kW 1.9 1.9 1.9 1.9 1.9 1.9
  Izlaz za vodu u toploj klimi 55 °C Općenito Godišnja potrošnja energije kWh 4,090 4,090 4,090 4,090 4,090 4,090
      Ƞs (sezonska učinkovitost grijanja prostora) % 160 160 160 160 160 160
      Pnazivno pri 2°C kW 13 13 13 13 13 13
      Qhe Godišnja potrošnja energije (GCV) Gj 15 15 15 15 15 15
    B Stanje (2 °C DB/1 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   2.45 2.45 2.45 2.45 2.45 2.45
      Pdh kW 10.0 10.0 10.0 10.0 10.0 10.0
      PERd % 98.0 98.0 98.0 98.0 98.0 98.0
    C Stanje (7 °C DB/6 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   3.69 3.69 3.69 3.69 3.69 3.69
      Pdh kW 7.9 7.9 7.9 7.9 7.9 7.9
      PERd % 147.6 147.6 147.6 147.6 147.6 147.6
    C Stanje (12 °C DB/11 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   5.39 5.39 5.39 5.39 5.39 5.39
      Pdh kW 5.9 5.9 5.9 5.9 5.9 5.9
      PERd % 215.6 215.6 215.6 215.6 215.6 215.6
    Tbiv (bivalentna temperatura) COPd   3.27 3.27 3.27 3.27 3.27 3.27
      Pdh kW 9.9 9.9 9.9 9.9 9.9 9.9
      PERd % 130.8 130.8 130.8 130.8 130.8 130.8
      Tbiv °C 5 5 5 5 5 5
  Space heating-=-Water outlet 45°C Space heating-=-Water outlet 45°C-=-H Condition (-2°C / - ) Space heating-=-Water outlet 45°C-=-H Condition (-2°C / - )-=-Max.-=-kW kW 11.1 11.1 11.8 11.8 11.8 11.8
  Izlaz za vodu u prosječnoj klimi 35°C Općenito SCOP   4.51 4.51 4.51 4.51 4.51 4.51
      Godišnja potrošnja energije kWh 5,726 5,726 5,726 5,726 5,726 5,726
      Ƞs (sezonska učinkovitost grijanja prostora) % 177 177 177 177 177 177
      Pnazivno pri -10°C kW 13 13 13 13 13 13
      Qhe Godišnja potrošnja energije (GCV) Gj 21 21 21 21 21 21
      Razred sezonske učinkovitosti grijanja prostora   A+++ A+++ A+++ A+++ A+++ A+++
    Stanje (-7 °C DB/-8 °C WB) COPd   3.12 3.12 3.12 3.12 3.12 3.12
      Pdh kW 11.1 11.1 11.1 11.1 11.1 11.1
      PERd % 124.8 124.8 124.8 124.8 124.8 124.8
    B Stanje (2 °C DB/1 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   4.44 4.44 4.44 4.44 4.44 4.44
      Pdh kW 6.7 6.7 6.7 6.7 6.7 6.7
      PERd % 177.6 177.6 177.6 177.6 177.6 177.6
    C Stanje (7 °C DB/6 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   5.84 5.84 5.84 5.84 5.84 5.84
      Pdh kW 5.7 5.7 5.7 5.7 5.7 5.7
      PERd % 233.6 233.6 233.6 233.6 233.6 233.6
    C Stanje (12 °C DB/11 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   7.40 7.40 7.40 7.40 7.40 7.40
      Pdh kW 6.0 6.0 6.0 6.0 6.0 6.0
      PERd % 296.0 296.0 296.0 296.0 296.0 296.0
    Tol (granična radna temperatura) COPd   2.76 2.76 2.76 2.76 2.76 2.76
      Pdh kW 11.1 11.1 11.1 11.1 11.1 11.1
      PERd % 110.4 110.4 110.4 110.4 110.4 110.4
      TOL °C -10 -10 -10 -10 -10 -10
      WTOL °C 35 35 35 35 35 35
    Tbiv (bivalentna temperatura) COPd   3.12 3.12 3.12 3.12 3.12 3.12
      Pdh kW 11.1 11.1 11.1 11.1 11.1 11.1
      PERd % 124.8 124.8 124.8 124.8 124.8 124.8
      Tbiv °C -7 -7 -7 -7 -7 -7
    Dopunski toplinski učin na izlazu Psup (pri Tdesign -10°C) kW 1.4 1.4 1.4 1.4 1.4 1.4
  Izlaz za vodu u hladnoj klimi 35 °C Općenito Godišnja potrošnja energije kWh 7,417 7,417 7,417 7,417 7,417 7,417
      Ƞs (sezonska učinkovitost grijanja prostora) % 163 163 163 163 163 163
      Pnazivno pri -22°C kW 13 13 13 13 13 13
      Qhe Godišnja potrošnja energije (GCV) Gj 27 27 27 27 27 27
    Stanje (-7 °C DB/-8 °C WB) COPd   3.50 3.50 3.50 3.50 3.50 3.50
      Pdh kW 8.0 8.0 8.0 8.0 8.0 8.0
      PERd % 140.0 140.0 140.0 140.0 140.0 140.0
    B Stanje (2 °C DB/1 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   5.07 5.07 5.07 5.07 5.07 5.07
      Pdh kW 4.9 4.9 4.9 4.9 4.9 4.9
      PERd % 202.8 202.8 202.8 202.8 202.8 202.8
    C Stanje (7 °C DB/6 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   6.10 6.10 6.10 6.10 6.10 6.10
      Pdh kW 5.3 5.3 5.3 5.3 5.3 5.3
      PERd % 244.0 244.0 244.0 244.0 244.0 244.0
    C Stanje (12 °C DB/11 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   7.03 7.03 7.03 7.03 7.03 7.03
      Pdh kW 5.7 5.7 5.7 5.7 5.7 5.7
      PERd % 281.2 281.2 281.2 281.2 281.2 281.2
    Tol (granična radna temperatura) COPd   2.16 2.16 2.16 2.16 2.16 2.16
      Pdh kW 10.1 10.1 10.1 10.1 10.1 10.1
      PERd % 86.4 86.4 86.4 86.4 86.4 86.4
      TOL °C -22 -22 -22 -22 -22 -22
      WTOL °C 35 35 35 35 35 35
    G Stanje (-15°CDB/-) COPd   2.62 2.62 2.62 2.62 2.62 2.62
      Pdh kW 10.7 10.7 10.7 10.7 10.7 10.7
      PERd % 104.8 104.8 104.8 104.8 104.8 104.8
    Tbiv (bivalentna temperatura) COPd   2.62 2.62 2.62 2.62 2.62 2.62
      Pdh kW 10.7 10.7 10.7 10.7 10.7 10.7
      PERd % 104.8 104.8 104.8 104.8 104.8 104.8
      Tbiv °C -15 -15 -15 -15 -15 -15
    Dopunski toplinski učin na izlazu Psup (pri Tdesign -22°C) kW 2.4 2.4 2.4 2.4 2.4 2.4
  Izlaz za vodu u toploj klimi 35°C Općenito Godišnja potrošnja energije kWh 2,885 2,885 2,885 2,885 2,885 2,885
      Ƞs (sezonska učinkovitost grijanja prostora) % 229 229 229 229 229 229
      Pnazivno pri 2°C kW 13 13 13 13 13 13
      Qhe Godišnja potrošnja energije (GCV) Gj 10 10 10 10 10 10
    B Stanje (2 °C DB/1 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   3.67 3.67 3.67 3.67 3.67 3.67
      Pdh kW 9.8 9.8 9.8 9.8 9.8 9.8
      PERd % 146.8 146.8 146.8 146.8 146.8 146.8
    C Stanje (7 °C DB/6 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   5.60 5.60 5.60 5.60 5.60 5.60
      Pdh kW 7.9 7.9 7.9 7.9 7.9 7.9
      PERd % 224.0 224.0 224.0 224.0 224.0 224.0
    Tbiv (bivalentna temperatura) COPd   4.95 4.95 4.95 4.95 4.95 4.95
      Pdh kW 9.8 9.8 9.8 9.8 9.8 9.8
      PERd % 198.0 198.0 198.0 198.0 198.0 198.0
      Tbiv °C 5 5 5 5 5 5
    C Stanje (12 °C DB/11 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   7.60 7.60 7.60 7.60 7.60 7.60
      Pdh kW 6.1 6.1 6.1 6.1 6.1 6.1
      PERd % 304.0 304.0 304.0 304.0 304.0 304.0
Notes_Description 1 1 1 1 1 1