Specifications Table for ETBH-D6V / EPRA014-018DW

ETBH16DA6V / EPRA14DAW1 ETBH16DA6V / EPRA16DAW1 ETBH16DA6V / EPRA18DAW1
Indoor unit ETBH16DA6V ETBH16DA6V ETBH16DA6V
Outdoor unit EPRA14DAW1 EPRA16DAW1 EPRA18DAW1
Učin grijanja Min. kW 3.50 (1) 3.90 (1) 4.16 (1)
  Nom. kW 5.69 (2) 9.00 (2) 9.00 (2)
  Maks. kW 8.75 (1) 10.00 (1) 11.25 (1)
Ulazna snaga Grijanje Min. kW 0.74 (3) 0.82 (3) 0.88 (3)
    Nom. kW 1.22 (2) 1.80 (2) 1.80 (2)
    Maks. kW 1.86 (3) 2.13 (3) 2.40 (3)
COP 4.66 (2) 5.00 (2) 5.00 (2)
Pumpa Type   Grundfos UPMXL GEO 25-125 130 PWM Grundfos UPMXL GEO 25-125 130 PWM Grundfos UPMXL GEO 25-125 130 PWM
  Nominalna ESP jedinica Grijanje kPa 111.2 (5) 97.4 (5) 97.4 (5)
Izmjenjivač topline na vodenoj strani Količina vode u cirkulaciji Grijanje Nom. l/min 16.3 (2) 25.8 (2) 25.8 (2)
Općenito Detalji o dobavljaču/proizvođaču Name and address   Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
    Naziv ili trgovački znak   Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V.
  Opis proizvoda Dizalica topline zrak-voda   Da Da Da
    Dizalica topline rasolina-u-vodu   Ne Ne Ne
    Dizalica topline u kombinaciji s grijačem   Da Da Da
    Niskotemperaturna dizalica topline   Ne Ne Ne
    Ugrađeni dodatni grijač   Da Da Da
    Dizalica topline voda-voda   Ne Ne Ne
  LW(A) Razina zvučne snage (u skladu s EN14825) Unutarnja dB(A) 44.0 44.0 44.0
LW(A) Razina zvučne snage (u skladu s EN14825) Vanjska dB(A) 54.0 54.0 54.0
Zvučna snaga u uvjetu Eko-dizajna i oznaka energetske učinkovitosti Zvučna snaga u režimu grijanja mjerena je prema EN12102 u uvjetima EN14825 Zvučna snaga u režimu grijanja mjerena je prema EN12102 u uvjetima EN14825 Zvučna snaga u režimu grijanja mjerena je prema EN12102 u uvjetima EN14825
Općenito grijanje prostora Ostalo Regulacija učina   Inverter Inverter Inverter
    Pck (grijač kućišta kolj. osovine) kW 0.000 0.000 0.000
    Poff (režim isključeno) kW 0.031 0.031 0.031
    Psb (načina rada u stanju mirovanja) kW 0.042 0.042 0.042
    Pto (termostat isključen) kW 0.033 0.033 0.033
  Ugrađeni dodatni grijač Psup kW 6.0 6.0 6.0
    Vrsta ulazne energije   Električni Električni Električni
Grijanje prostora Izlaz za vodu u prosječnoj klimi 55°C Općenito Godišnja potrošnja energije kWh 7,236 7,236 7,236
      Ƞs (sezonska učinkovitost grijanja prostora) % 140 140 140
      Pnazivno pri -10°C kW 13 13 13
      Qhe Godišnja potrošnja energije (GCV) Gj 26 26 26
      SCOP   3.57 3.57 3.57
      Razred sezonske učinkovitosti grijanja prostora   A++ A++ A++
    Stanje (-7 °C DB/-8 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0
      COPd   2.43 2.43 2.43
      Pdh kW 11.1 11.1 11.1
      PERd % 97.2 97.2 97.2
    B Stanje (2 °C DB/1 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0
      COPd   3.52 3.52 3.52
      Pdh kW 6.7 6.7 6.7
      PERd % 140.8 140.8 140.8
    C Stanje (7 °C DB/6 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0
      COPd   4.54 4.54 4.54
      Pdh kW 6.5 6.5 6.5
      PERd % 181.6 181.6 181.6
    C Stanje (12 °C DB/11 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0
      COPd   5.97 5.97 5.97
      Pdh kW 5.2 5.2 5.2
      PERd % 238.8 238.8 238.8
    Tol (granična radna temperatura) COPd   2.12 2.12 2.12
      Pdh kW 12.5 12.5 12.5
      PERd % 84.8 84.8 84.8
      TOL °C -10 -10 -10
      WTOL °C 55 55 55
    Dopunski toplinski učin na izlazu Psup (pri Tdesign -10°C) kW 0.0 0.0 0.0
    Tbiv (bivalentna temperatura) COPd   2.12 2.12 2.12
      Pdh kW 12.5 12.5 12.5
      PERd % 84.8 84.8 84.8
      Tbiv °C -10 -10 -10
  Izlaz za vodu u hladnoj klimi 55°C Općenito Godišnja potrošnja energije kWh 9,658 9,658 9,658
      Ƞs (sezonska učinkovitost grijanja prostora) % 125 125 125
      Pnazivno pri -22°C kW 13 13 13
      Qhe Godišnja potrošnja energije (GCV) Gj 35 35 35
    Stanje (-7 °C DB/-8 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0
      COPd   2.74 2.74 2.74
      Pdh kW 7.5 7.5 7.5
      PERd % 109.6 109.6 109.6
    B Stanje (2 °C DB/1 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0
      COPd   3.67 3.67 3.67
      Pdh kW 5.8 5.8 5.8
      PERd % 146.8 146.8 146.8
    C Stanje (7 °C DB/6 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0
      COPd   4.69 4.69 4.69
      Pdh kW 5.6 5.6 5.6
      PERd % 187.6 187.6 187.6
    C Stanje (12 °C DB/11 °C WB) COPd   6.12 6.12 6.12
      Pdh kW 6.2 6.2 6.2
      PERd % 244.8 244.8 244.8
    Tol (granična radna temperatura) COPd   1.65 1.65 1.65
      Pdh kW 10.6 10.6 10.6
      PERd % 66.0 66.0 66.0
      TOL °C -22 -22 -22
      WTOL °C 55 55 55
    G Stanje (-15°CDB/-) COPd   2.17 2.17 2.17
      Pdh kW 10.3 10.3 10.3
      PERd % 86.8 86.8 86.8
    Tbiv (bivalentna temperatura) COPd   1.90 1.90 1.90
      Pdh kW 11.0 11.0 11.0
      PERd % 76.0 76.0 76.0
      Tbiv °C -18 -18 -18
    Dopunski toplinski učin na izlazu Psup (pri Tdesign -22°C) kW 1.9 1.9 1.9
  Izlaz za vodu u toploj klimi 55 °C Općenito Godišnja potrošnja energije kWh 4,063 4,063 4,063
      Ƞs (sezonska učinkovitost grijanja prostora) % 161 161 161
      Pnazivno pri 2°C kW 13 13 13
      Qhe Godišnja potrošnja energije (GCV) Gj 15 15 15
    B Stanje (2 °C DB/1 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0
      COPd   2.62 2.62 2.62
      Pdh kW 11.4 11.4 11.4
      PERd % 104.8 104.8 104.8
    C Stanje (7 °C DB/6 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0
      COPd   3.65 3.65 3.65
      Pdh kW 8.2 8.2 8.2
      PERd % 146.0 146.0 146.0
    C Stanje (12 °C DB/11 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0
      COPd   5.37 5.37 5.37
      Pdh kW 6.1 6.1 6.1
      PERd % 214.8 214.8 214.8
    Tbiv (bivalentna temperatura) COPd   3.18 3.18 3.18
      Pdh kW 11.0 11.0 11.0
      PERd % 127.2 127.2 127.2
      Tbiv °C 4 4 4
  Space heating-=-Water outlet 45°C Space heating-=-Water outlet 45°C-=-H Condition (-2°C / - ) Space heating-=-Water outlet 45°C-=-H Condition (-2°C / - )-=-Max.-=-kW kW 11.1 11.8 11.8
  Izlaz za vodu u prosječnoj klimi 35°C Općenito SCOP   4.48 4.48 4.48
      Godišnja potrošnja energije kWh 5,765 5,765 5,765
      Ƞs (sezonska učinkovitost grijanja prostora) % 176 176 176
      Pnazivno pri -10°C kW 13 13 13
      Qhe Godišnja potrošnja energije (GCV) Gj 21 21 21
      Razred sezonske učinkovitosti grijanja prostora   A+++ A+++ A+++
    Stanje (-7 °C DB/-8 °C WB) COPd   3.07 3.07 3.07
      Pdh kW 10.6 10.6 10.6
      PERd % 122.8 122.8 122.8
    B Stanje (2 °C DB/1 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0
      COPd   4.49 4.49 4.49
      Pdh kW 6.5 6.5 6.5
      PERd % 179.6 179.6 179.6
    C Stanje (7 °C DB/6 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0
      COPd   5.75 5.75 5.75
      Pdh kW 6.1 6.1 6.1
      PERd % 230.0 230.0 230.0
    C Stanje (12 °C DB/11 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0
      COPd   6.97 6.97 6.97
      Pdh kW 5.5 5.5 5.5
      PERd % 278.8 278.8 278.8
    Tol (granična radna temperatura) COPd   2.84 2.84 2.84
      Pdh kW 11.8 11.8 11.8
      PERd % 113.6 113.6 113.6
      TOL °C -10 -10 -10
      WTOL °C 35 35 35
    Tbiv (bivalentna temperatura) COPd   3.13 3.13 3.13
      Pdh kW 10.6 10.6 10.6
      PERd % 125.2 125.2 125.2
      Tbiv °C -7 -7 -7
    Dopunski toplinski učin na izlazu Psup (pri Tdesign -10°C) kW 0.7 0.7 0.7
  Izlaz za vodu u hladnoj klimi 35 °C Općenito Godišnja potrošnja energije kWh 7,425 7,425 7,425
      Ƞs (sezonska učinkovitost grijanja prostora) % 163 163 163
      Pnazivno pri -22°C kW 13 13 13
      Qhe Godišnja potrošnja energije (GCV) Gj 27 27 27
    Stanje (-7 °C DB/-8 °C WB) COPd   3.50 3.50 3.50
      Pdh kW 8.0 8.0 8.0
      PERd % 140.0 140.0 140.0
    B Stanje (2 °C DB/1 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0
      COPd   5.07 5.07 5.07
      Pdh kW 4.9 4.9 4.9
      PERd % 202.8 202.8 202.8
    C Stanje (7 °C DB/6 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0
      COPd   6.10 6.10 6.10
      Pdh kW 5.3 5.3 5.3
      PERd % 244.0 244.0 244.0
    C Stanje (12 °C DB/11 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0
      COPd   7.03 7.03 7.03
      Pdh kW 5.7 5.7 5.7
      PERd % 281.2 281.2 281.2
    Tol (granična radna temperatura) COPd   2.16 2.16 2.16
      Pdh kW 10.1 10.1 10.1
      PERd % 86.4 86.4 86.4
      TOL °C -22 -22 -22
      WTOL °C 35 35 35
    G Stanje (-15°CDB/-) COPd   2.62 2.62 2.62
      Pdh kW 10.7 10.7 10.7
      PERd % 104.8 104.8 104.8
    Tbiv (bivalentna temperatura) COPd   2.62 2.62 2.62
      Pdh kW 10.7 10.7 10.7
      PERd % 104.8 104.8 104.8
      Tbiv °C -15 -15 -15
    Dopunski toplinski učin na izlazu Psup (pri Tdesign -22°C) kW 2.4 2.4 2.4
  Izlaz za vodu u toploj klimi 35°C Općenito Godišnja potrošnja energije kWh 2,992 2,992 2,992
      Ƞs (sezonska učinkovitost grijanja prostora) % 220 220 220
      Pnazivno pri 2°C kW 13 13 13
      Qhe Godišnja potrošnja energije (GCV) Gj 11 11 11
    B Stanje (2 °C DB/1 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0
      COPd   3.51 3.51 3.51
      Pdh kW 10.0 10.0 10.0
      PERd % 140.4 140.4 140.4
    C Stanje (7 °C DB/6 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0
      COPd   5.67 5.67 5.67
      Pdh kW 8.3 8.3 8.3
      PERd % 226.8 226.8 226.8
    Tbiv (bivalentna temperatura) COPd   4.96 4.96 4.96
      Pdh kW 9.8 9.8 9.8
      PERd % 198.4 198.4 198.4
      Tbiv °C 5 5 5
    C Stanje (12 °C DB/11 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0
      COPd   7.04 7.04 7.04
      Pdh kW 5.7 5.7 5.7
      PERd % 281.6 281.6 281.6
Napomene (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C (1) - Capacity according to standard EN14511 and valid for heated water range dT = 3~8°C at Ta 7°C
  (2) - Uvjet: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Uvjet: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (2) - Uvjet: Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (3) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (3) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511 (3) - Power input is total input of indoor and outdoor units, including the circulation pump; according to EN14511
  (4) - Ispitano pri Ta DB/WB 7 °C/6 °C prema EN 16147. (4) - Ispitano pri Ta DB/WB 7 °C/6 °C prema EN 16147. (4) - Ispitano pri Ta DB/WB 7 °C/6 °C prema EN 16147.
  (5) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed (5) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed (5) - DB/WB 7°C/6°C - LWC 35°C (dT=5°C) with pump at full speed