EAVH16S23DA6V / EPGA11DAV3 EAVH16S18DA6V / EPGA11DAV3 EAVH16S23DA6V / EPGA14DAV3 EAVH16S18DA6V / EPGA14DAV3 EAVH16S23DA6V / EPGA16DAV3 EAVH16S18DA6V / EPGA16DAV3
Indoor unit EAVH16S23DA6V EAVH16S18DA6V EAVH16S23DA6V EAVH16S18DA6V EAVH16S23DA6V EAVH16S18DA6V
Outdoor unit EPGA11DAV3 EPGA11DAV3 EPGA14DAV3 EPGA14DAV3 EPGA16DAV3 EPGA16DAV3
Učin grijanja Nom. kW 11.1 (1), 11.3 (2) 11.1 (1), 11.3 (2) 14.5 (1), 14.5 (2) 14.5 (1), 14.5 (2) 16.5 (1), 15.6 (2) 16.5 (1), 15.6 (2)
Ulazna snaga Grijanje Nom. kW 2.16 (1), 2.91 (2) 2.16 (1), 2.91 (2) 2.91 (1), 3.96 2.91 (1), 3.96 3.45 (1), 4.21 (2) 3.45 (1), 4.21 (2)
  Potrošna topla voda od 10°C do 50 °C Nom. kWh 3.08 2.67 3.08 2.67 3.08 2.67
Heat up time from 10°C to 50°C hr 1h02min at 7°C ambient temperature 53min at 7°C ambient temperature 1h02min at 7°C ambient temperature 53min at 7°C ambient temperature 1h02min at 7°C ambient temperature 53min at 7°C ambient temperature
COP 5.15 (1), 3.88 (2) 5.15 (1), 3.88 (2) 4.99 (1), 3.65 (2) 4.99 (1), 3.65 (2) 4.78 (1), 3.71 (2) 4.78 (1), 3.71 (2)
Pumpa Type   Grundfos UPMXL GEO 25-125 130 PWM Grundfos UPMXL GEO 25-125 130 PWM Grundfos UPMXL GEO 25-125 130 PWM Grundfos UPMXL GEO 25-125 130 PWM Grundfos UPMXL GEO 25-125 130 PWM Grundfos UPMXL GEO 25-125 130 PWM
  Nominalna ESP jedinica Grijanje kPa 78.6 (1), 78.9 (2) 78.6 (1), 78.9 (2) 53.8 (1), 52.7 (2) 53.8 (1), 52.7 (2) 40.6 (1), 42.0 (2) 40.6 (1), 42.0 (2)
Izmjenjivač topline na vodenoj strani Količina vode u cirkulaciji Grijanje Nom. l/min 32.5 (1), 32.4 (2) 32.5 (1), 32.4 (2) 41.2 (1), 41.5 (2) 41.2 (1), 41.5 (2) 45.1 (1), 44.7 (2) 45.1 (1), 44.7 (2)
Općenito Detalji o dobavljaču/proizvođaču Name and address   Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium Daikin Europe N.V. - Zandvoordestraat 300, 8400 Oostende, Belgium
    Naziv ili trgovački znak   Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V. Daikin Europe N.V.
  Opis proizvoda Dizalica topline zrak-voda   Da Da Da Da Da Da
    Dizalica topline rasolina-u-vodu   Ne Ne Ne Ne Ne Ne
    Dizalica topline u kombinaciji s grijačem   Da Da Da Da Da Da
    Niskotemperaturna dizalica topline   Ne Ne Ne Ne Ne Ne
    Ugrađeni dodatni grijač   Da Da Da Da Da Da
    Dizalica topline voda-voda   Ne Ne Ne Ne Ne Ne
  LW(A) Razina zvučne snage (u skladu s EN14825) Unutarnja dB(A) 44.0 44.0 44.0 44.0 44.0 44.0
LW(A) Razina zvučne snage (u skladu s EN14825) Vanjska dB(A) 64.0 64.0 64.0 64.0 66.0 66.0
Zvučna snaga u uvjetu Eko-dizajna i oznaka energetske učinkovitosti Zvučna snaga u režimu grijanja mjerena je prema EN12102 u uvjetima EN14825 Zvučna snaga u režimu grijanja mjerena je prema EN12102 u uvjetima EN14825 Zvučna snaga u režimu grijanja mjerena je prema EN12102 u uvjetima EN14825 Zvučna snaga u režimu grijanja mjerena je prema EN12102 u uvjetima EN14825 Zvučna snaga u režimu grijanja mjerena je prema EN12102 u uvjetima EN14825 Zvučna snaga u režimu grijanja mjerena je prema EN12102 u uvjetima EN14825
Općenito grijanje prostora Zrak-voda jedinica Nazivni protok zraka (vanjska jedinica) m³/h 6,900 6,900 6,900 6,900 8,100 8,100
  Ostalo Regulacija učina   Inverter Inverter Inverter Inverter Inverter Inverter
    Pck (grijač kućišta kolj. osovine) kW 0.000 0.000 0.000 0.000 0.000 0.000
    Poff (režim isključeno) kW 0.021 0.021 0.021 0.021 0.021 0.021
    Psb (načina rada u stanju mirovanja) kW 0.021 0.021 0.021 0.021 0.021 0.021
    Pto (termostat isključen) kW 0.041 0.041 0.041 0.041 0.041 0.041
  Ugrađeni dodatni grijač Psup kW 6.0 6.0 6.0 6.0 6.0 6.0
    Vrsta ulazne energije   Električni Električni Električni Električni Električni Električni
Grijanje potrošne tople vode Općenito Deklarirani profil opterećenja   XL L XL L XL L
    Funkcija za utvrđivanje grijanja vode tijekom sati jeftinije električne energije   Da Da Da Da Da Da
  Prosječni klimatski uvjeti AEC (godišnja potrošnja električne energije) kWh 1,513 1,029 1,513 1,029 1,513 1,029
    AFC (godišnja potrošnja goriva) Gj 5.45 3.70 5.45 3.70 5.45 3.70
    Ƞwh (water heating efficiency) % 112 104 112 104 112 104
    Qelec (dnevna potrošnja električne energije) kWh 7.090 4.870 7.090 4.870 7.090 4.870
    Razred energetske učinkovitosti grijanja vode   A A A A A A
  Hladni klimatski uvjeti AEC (godišnja potrošnja električne energije) kWh 1,851 1,066 1,851 1,066 1,851 1,066
    AFC(godišnja potrošnja goriva) Gj 6.66 3.84 6.66 3.84 6.66 3.84
    Ƞwh (učinkovitost grijanja vode) % 91 100 91 100 91 100
    Qelec (dnevna potrošnja električne energije) kWh 8.850 5.195 8.850 5.195 8.850 5.195
  Topli klimatski uvjeti AEC (godišnja potrošnja električne energije) kWh 1,301 749 1,301 749 1,301 749
    AFC (godišnja potrošnja goriva) Gj 4.68 2.70 4.68 2.70 4.68 2.70
    Ƞwh (učinkovitost grijanja vode) % 130 142 130 142 130 142
    Qelec (dnevna potrošnja električne energije) kWh 6.160 3.590 6.160 3.590 6.160 3.590
Grijanje prostora Izlaz za vodu u prosječnoj klimi 55°C Općenito Godišnja potrošnja energije kWh 7,845 7,845 8,669 8,669 9,706 9,706
      Ƞs (sezonska učinkovitost grijanja prostora) % 129 129 130 130 133 133
      Pnazivno pri -10°C kW 13 13 14 14 16 16
      Qhe Godišnja potrošnja energije (GCV) Gj 28.2 28.2 31.2 31.2 34.9 34.9
      SCOP   3.29 3.29 3.34 3.34 3.41 3.41
      Razred sezonske učinkovitosti grijanja prostora   A++ A++ A++ A++ A++ A++
    Stanje (-7 °C DB/-8 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   2.25 2.25 2.17 2.17 2.23 2.23
      Pdh kW 11.5 11.5 12.3 12.3 13.1 13.1
      PERd % 90.0 90.0 86.8 86.8 89.2 89.2
    B Stanje (2 °C DB/1 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   3.14 3.14 3.18 3.18 3.26 3.26
      Pdh kW 6.5 6.5 8.1 8.1 8.7 8.7
      PERd % 125.6 125.6 127.2 127.2 130.4 130.4
    C Stanje (7 °C DB/6 °C WB) Cdh (grijanje razgradnjom)   0.96 0.96 1.0 1.0 1.0 1.0
      COPd   4.27 4.27 4.46 4.46 4.62 4.62
      Pdh kW 4.6 4.6 5.0 5.0 5.8 5.8
      PERd % 170.8 170.8 178.4 178.4 184.8 184.8
    C Stanje (12 °C DB/11 °C WB) Cdh (grijanje razgradnjom)   0.95 0.95 0.95 0.95 0.95 0.95
      COPd   5.75 5.75 5.94 5.94 6.47 6.47
      Pdh kW 5.2 5.2 5.2 5.2 5.2 5.2
      PERd % 230.0 230.0 237.6 237.6 258.8 258.8
    Tol (granična radna temperatura) COPd   2.11 2.11 2.10 2.10 2.05 2.05
      Pdh kW 12.5 12.5 13.5 13.5 13.2 13.2
      PERd % 84.4 84.4 84.0 84.0 82.0 82.0
      TOL °C -10 -10 -10 -10 -10 -10
      WTOL °C 55 55 55 55 55 55
    Dopunski toplinski učin na izlazu Psup (pri Tdesign -10°C) kW 0.0 0.0 0.5 0.5 2.8 2.8
    Tbiv (bivalentna temperatura) COPd   2.11 2.11 2.17 2.17 2.40 2.40
      Pdh kW 12.5 12.5 12.3 12.3 12.9 12.9
      PERd % 84.4 84.4 86.8 86.8 96.0 96.0
      Tbiv °C -10 -10 -7 -7 -5 -5
  Izlaz za vodu u hladnoj klimi 55°C Općenito Godišnja potrošnja energije kWh 10,085 10,085 11,385 11,385 12,295 12,295
      Ƞs (sezonska učinkovitost grijanja prostora) % 124 124 123 123 121 121
      Pnazivno pri -22°C kW 13 13 15 15 15 15
      Qhe Godišnja potrošnja energije (GCV) Gj 36.3 36.3 41.0 41.0 44.3 44.3
    Stanje (-7 °C DB/-8 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   2.68 2.68 2.61 2.61 2.58 2.58
      Pdh kW 8.3 8.3 8.8 8.8 9.4 9.4
      PERd % 107.2 107.2 104.4 104.4 103.2 103.2
    B Stanje (2 °C DB/1 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   3.75 3.75 3.75 3.75 3.66 3.66
      Pdh kW 5.1 5.1 5.5 5.5 5.9 5.9
      PERd % 150.0 150.0 150.0 150.0 146.4 146.4
    C Stanje (7 °C DB/6 °C WB) Cdh (grijanje razgradnjom)   0.96 0.96 0.96 0.96 0.96 0.96
      COPd   4.63 4.63 4.70 4.70 4.75 4.75
      Pdh kW 4.5 4.5 4.5 4.5 4.5 4.5
      PERd % 185.2 185.2 188.0 188.0 190.0 190.0
    C Stanje (12 °C DB/11 °C WB) COPd   6.01 6.01 6.13 6.13 6.21 6.21
      Pdh kW 5.2 5.2 5.2 5.2 5.1 5.1
      PERd % 240.4 240.4 245.2 245.2 248.4 248.4
    Tol (granična radna temperatura) COPd   1.34 1.34 1.34 1.34 1.34 1.34
      Pdh kW 7.5 7.5 7.5 7.5 7.5 7.5
      PERd % 53.6 53.6 53.6 53.6 53.6 53.6
      TOL °C -21 -21 -21 -21 -21 -21
      WTOL °C 54 54 54 54 54 54
    G Stanje (-15°CDB/-) COPd   2.10 2.10 2.12 2.12 2.13 2.13
      Pdh kW 11.1 11.1 11.9 11.9 12.6 12.6
      PERd % 84.0 84.0 84.8 84.8 85.2 85.2
    Tbiv (bivalentna temperatura) COPd   1.93 1.93 2.05 2.05 2.13 2.13
      Pdh kW 11.4 11.4 12.4 12.4 12.6 12.6
      PERd % 77.2 77.2 82.0 82.0 85.2 85.2
      Tbiv °C -18 -18 -16 -16 -15 -15
    Dopunski toplinski učin na izlazu Psup (pri Tdesign -22°C) kW 5.5 5.5 7.0 7.0 7.9 7.9
  Izlaz za vodu u toploj klimi 55 °C Općenito Godišnja potrošnja energije kWh 3,696 3,696 4,104 4,104 4,362 4,362
      Ƞs (sezonska učinkovitost grijanja prostora) % 156 156 160 160 162 162
      Pnazivno pri 2°C kW 11 11 13 13 14 14
      Qhe Godišnja potrošnja energije (GCV) Gj 13.3 13.3 14.8 14.8 15.7 15.7
    B Stanje (2 °C DB/1 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   2.45 2.45 2.43 2.43 2.41 2.41
      Pdh kW 11.4 11.4 12.4 12.4 13.5 13.5
      PERd % 98.0 98.0 97.2 97.2 96.4 96.4
    C Stanje (7 °C DB/6 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   3.58 3.58 3.62 3.62 3.66 3.66
      Pdh kW 7.2 7.2 7.9 7.9 8.7 8.7
      PERd % 143.2 143.2 144.8 144.8 146.4 146.4
    C Stanje (12 °C DB/11 °C WB) Cdh (grijanje razgradnjom)   0.96 0.96 0.96 0.96 0.96 0.96
      COPd   5.16 5.16 5.29 5.29 5.38 5.38
      Pdh kW 5.3 5.3 5.2 5.2 5.2 5.2
      PERd % 206.4 206.4 211.6 211.6 215.2 215.2
    Tbiv (bivalentna temperatura) COPd   2.45 2.45 2.43 2.43 2.41 2.41
      Pdh kW 11.4 11.4 12.4 12.4 13.5 13.5
      PERd % 98.0 98.0 97.2 97.2 96.4 96.4
      Tbiv °C 2 2 2 2 2 2
  Izlaz za vodu u prosječnoj klimi 35°C Općenito SCOP   4.38 4.38 4.45 4.45 4.56 4.56
      Godišnja potrošnja energije kWh 5,189 5,189 5,797 5,797 6,345 6,345
      Ƞs (sezonska učinkovitost grijanja prostora) % 172 172 175 175 179 179
      Pnazivno pri -10°C kW 11 11 13 13 14 14
      Qhe Godišnja potrošnja energije (GCV) Gj 18.7 18.7 20.9 20.9 22.8 22.8
      Razred sezonske učinkovitosti grijanja prostora   A++ A++ A++ A++ A++ A++
    Stanje (-7 °C DB/-8 °C WB) COPd   3.07 3.07 2.85 2.85 2.99 2.99
      Pdh kW 9.7 9.7 11.1 11.1 12.2 12.2
      PERd % 122.8 122.8 114.0 114.0 119.6 119.6
    B Stanje (2 °C DB/1 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   4.15 4.15 4.24 4.24 4.30 4.30
      Pdh kW 6.3 6.3 7.0 7.0 7.4 7.4
      PERd % 166.0 166.0 169.6 169.6 172.0 172.0
    C Stanje (7 °C DB/6 °C WB) Cdh (grijanje razgradnjom)   0.95 0.95 1.0 1.0 0.95 0.95
      COPd   5.86 5.86 6.24 6.24 6.35 6.35
      Pdh kW 4.5 4.5 4.5 4.5 5.0 5.0
      PERd % 234.4 234.4 249.6 249.6 254.0 254.0
    C Stanje (12 °C DB/11 °C WB) Cdh (grijanje razgradnjom)   0.94 0.94 0.94 0.94 0.94 0.94
      COPd   7.88 7.88 8.12 8.12 8.12 8.12
      Pdh kW 5.3 5.3 5.3 5.3 5.3 5.3
      PERd % 315.2 315.2 324.8 324.8 324.8 324.8
    Tol (granična radna temperatura) COPd   2.80 2.80 2.53 2.53 2.72 2.72
      Pdh kW 11.0 11.0 12.5 12.5 14.5 14.5
      PERd % 112.0 112.0 101.2 101.2 108.8 108.8
      TOL °C -10 -10 -10 -10 -10 -10
      WTOL °C 35 35 35 35 35 35
    Tbiv (bivalentna temperatura) COPd   2.80 2.80 2.53 2.53 2.72 2.72
      Pdh kW 11.0 11.0 12.5 12.5 14.5 14.5
      PERd % 112.0 112.0 101.2 101.2 108.8 108.8
      Tbiv °C -10 -10 -10 -10 -10 -10
    Dopunski toplinski učin na izlazu Psup (pri Tdesign -10°C) kW 0.0 0.0 0.0 0.0 0.0 0.0
  Izlaz za vodu u hladnoj klimi 35 °C Općenito Godišnja potrošnja energije kWh 9,295 9,295 10,249 10,249 11,108 11,108
      Ƞs (sezonska učinkovitost grijanja prostora) % 151 151 151 151 157 157
      Pnazivno pri -22°C kW 15 15 16 16 18 18
      Qhe Godišnja potrošnja energije (GCV) Gj 33.5 33.5 36.9 36.9 40.0 40.0
    Stanje (-7 °C DB/-8 °C WB) COPd   3.09 3.09 3.20 3.20 3.39 3.39
      Pdh kW 9.0 9.0 9.7 9.7 10.8 10.8
      PERd % 123.6 123.6 128.0 128.0 135.6 135.6
    B Stanje (2 °C DB/1 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 0.97 0.97
      COPd   4.45 4.45 4.45 4.45 4.68 4.68
      Pdh kW 5.6 5.6 5.6 5.6 7.1 7.1
      PERd % 178.0 178.0 178.0 178.0 187.2 187.2
    C Stanje (7 °C DB/6 °C WB) Cdh (grijanje razgradnjom)   0.94 0.94 0.94 0.94 0.94 0.94
      COPd   6.24 6.24 6.46 6.46 6.75 6.75
      Pdh kW 4.5 4.5 4.5 4.5 4.6 4.6
      PERd % 249.6 249.6 258.4 258.4 270.0 270.0
    C Stanje (12 °C DB/11 °C WB) Cdh (grijanje razgradnjom)   0.94 0.94 0.94 0.94 0.94 0.94
      COPd   7.84 7.84 7.98 7.98 8.19 8.19
      Pdh kW 5.2 5.2 5.3 5.3 5.3 5.3
      PERd % 313.6 313.6 319.2 319.2 327.6 327.6
    Tol (granična radna temperatura) COPd   2.13 2.13 2.10 2.10 2.10 2.10
      Pdh kW 11.8 11.8 13.5 13.5 13.5 13.5
      PERd % 85.2 85.2 84.0 84.0 84.0 84.0
      TOL °C -22 -22 -22 -22 -22 -22
      WTOL °C 35 35 35 35 35 35
    G Stanje (-15°CDB/-) COPd   2.67 2.67 2.43 2.43 2.40 2.40
      Pdh kW 12.1 12.1 13.4 13.4 14.6 14.6
      PERd % 106.8 106.8 97.2 97.2 96.0 96.0
    Tbiv (bivalentna temperatura) COPd   2.49 2.49 2.36 2.36 2.40 2.40
      Pdh kW 13.1 13.1 13.7 13.7 14.6 14.6
      PERd % 99.6 99.6 94.4 94.4 96.0 96.0
      Tbiv °C -18 -18 -16 -16 -15 -15
    Dopunski toplinski učin na izlazu Psup (pri Tdesign -22°C) kW 2.7 2.7 2.5 2.5 4.5 4.5
  Izlaz za vodu u toploj klimi 35°C Općenito Godišnja potrošnja energije kWh 2,496 2,496 2,779 2,779 3,136 3,136
      Ƞs (sezonska učinkovitost grijanja prostora) % 233 233 237 237 236 236
      Pnazivno pri 2°C kW 11 11 13 13 14 14
      Qhe Godišnja potrošnja energije (GCV) Gj 8.99 8.99 10.0 10.0 11.3 11.3
    B Stanje (2 °C DB/1 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   3.40 3.40 3.25 3.25 3.22 3.22
      Pdh kW 11.1 11.1 12.4 12.4 12.7 12.7
      PERd % 136.0 136.0 130.0 130.0 128.8 128.8
    C Stanje (7 °C DB/6 °C WB) Cdh (grijanje razgradnjom)   1.0 1.0 1.0 1.0 1.0 1.0
      COPd   5.67 5.67 5.70 5.70 5.73 5.73
      Pdh kW 7.6 7.6 8.4 8.4 9.3 9.3
      PERd % 226.8 226.8 228.0 228.0 229.2 229.2
    Tbiv (bivalentna temperatura) COPd   3.40 3.40 3.25 3.25 3.44 3.44
      Pdh kW 11.1 11.1 12.4 12.4 12.2 12.2
      PERd % 136.0 136.0 130.0 130.0 137.6 137.6
      Tbiv °C 2 2 2 2 4 4
    C Stanje (12 °C DB/11 °C WB) Cdh (grijanje razgradnjom)   0.94 0.94 0.94 0.94 0.94 0.94
      COPd   7.60 7.60 7.78 7.78 8.03 8.03
      Pdh kW 5.2 5.2 5.3 5.3 5.3 5.3
      PERd % 304.0 304.0 311.2 311.2 321.2 321.2
Napomene (1) - Stanje 1: hlađenje Ta 35°C - LWE 18°C (DT = 5°C); grijanje Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Stanje 1: hlađenje Ta 35°C - LWE 18°C (DT = 5°C); grijanje Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Stanje 1: hlađenje Ta 35°C - LWE 18°C (DT = 5°C); grijanje Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Stanje 1: hlađenje Ta 35°C - LWE 18°C (DT = 5°C); grijanje Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Stanje 1: hlađenje Ta 35°C - LWE 18°C (DT = 5°C); grijanje Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Stanje 1: hlađenje Ta 35°C - LWE 18°C (DT = 5°C); grijanje Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (2) - Stanje 2: hlađenje Ta 35°C - LWE 7°C (DT = 5°C); grijanje Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) (2) - Stanje 2: hlađenje Ta 35°C - LWE 7°C (DT = 5°C); grijanje Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) (2) - Stanje 2: hlađenje Ta 35°C - LWE 7°C (DT = 5°C); grijanje Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) (2) - Stanje 2: hlađenje Ta 35°C - LWE 7°C (DT = 5°C); grijanje Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) (2) - Stanje 2: hlađenje Ta 35°C - LWE 7°C (DT = 5°C); grijanje Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C) (2) - Stanje 2: hlađenje Ta 35°C - LWE 7°C (DT = 5°C); grijanje Ta DB/WB 7°C/6°C - LWC 45°C (DT = 5°C)